JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nehmeh, S. A.
Right arrow Articles by Humm, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nehmeh, S. A.
Right arrow Articles by Humm, J. L.
Journal of Nuclear Medicine Vol. 44 No. 10 1644-1648
© 2003 by Society of Nuclear Medicine


Brief Communications

Reduction of Respiratory Motion Artifacts in PET Imaging of Lung Cancer by Respiratory Correlated Dynamic PET: Methodology and Comparison with Respiratory Gated PET

Sadek A. Nehmeh, PhD1, Yusuf E. Erdi, DSc1, Kenneth E. Rosenzweig, MD2, Heiko Schoder, MD3, Steve M. Larson, MD3, Olivia D. Squire, BA3 and John L. Humm, PhD1

1 Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York
2 Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York
3 Department of Radiology, Nuclear Medicine Service, Memorial Sloan-Kettering Cancer Center, New York, New York

ABSTRACT

This study proposes a new method to reduce respiratory motion artifacts in PET images of lung cancer. The method is referred to as respiratory-correlated dynamic PET (RCDPET). RCDPET enables the acquisition of 4-dimensional PET data without the need for a respiratory tracking device. In this article, we compare this method with respiratory-gated PET (RGPET). Both methods provide the ability to correct for motion artifacts and more accurately quantitate radiotracer uptake within lung lesions. Both methods were evaluated in phantom studies and 1 patient. Methods: With RCDPET, data are acquired in consecutive 1-s time frames. A point source attached to a rigid foam block is set on the patient’s abdomen and is extended into the camera field of view at the level of the lesion by means of a low-density rod. The position of this source is used to track respiratory motion through the consecutive dynamic frames. Image frames corresponding to a user-selected lesion position within the breathing cycle, in correlation with the point source position, are then identified after scanning. The sinograms of the selected image frames are summed and then reconstructed using iterative reconstruction with segmented attenuation correction. Results: The results from phantom studies with both RGPET and RCDPET were within 10% agreement, for both activity quantitation and image noise levels. In a clinical application, the quantitation of the SUVmax and the lesion’s size showed a 6% and 2% difference, respectively, between RCDPET and RGPET measurements. Conclusion: RCDPET can be considered as a comparable, or alternative, method to RGPET in reducing the smearing effects due to respiration and improving quantitation of PET in the thorax. One advantage of RCDPET over RGPET is the ability to retrospectively reconstruct the PET data at any phase or amplitude in the breathing cycle.

Key Words: PET • respiratory-gated PET • respiratory-correlated dynamic PET




This article has been cited by other articles:


Home page
JNMHome page
T. Kawano, E. Ohtake, and T. Inoue
Deep-Inspiration Breath-Hold PET/CT of Lung Cancer: Maximum Standardized Uptake Value Analysis of 108 Patients
J. Nucl. Med., August 1, 2008; 49(8): 1223 - 1231.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Suga, Y. Kawakami, H. Iwanaga, O. Tokuda, and N. Matsunaga
Automated Breath-Hold Perfusion SPECT/CT Fusion Images of the Lungs
Am. J. Roentgenol., August 1, 2007; 189(2): 455 - 463.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P H Jarritt, K J Carson, A R Hounsell, and D Visvikis
The role of PET/CT scanning in radiotherapy planning
Br. J. Radiol., September 1, 2006; 79(Special_Issue_1): S27 - S35.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. J. Jaskowiak, J. A. Bianco, S. B. Perlman, and J. P. Fine
Influence of Reconstruction Iterations on 18F-FDG PET/CT Standardized Uptake Values
J. Nucl. Med., March 1, 2005; 46(3): 424 - 428.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. C. Detterbeck, J. F. Vansteenkiste, D. E. Morris, C. A. Dooms, A. H. Khandani, and M. A. Socinski
Seeking a Home for a PET, Part 3: Emerging Applications of Positron Emission Tomography Imaging in the Management of Patients With Lung Cancer
Chest, November 1, 2004; 126(5): 1656 - 1666.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2003 by the Society of Nuclear Medicine.