JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pitman, A. G.
Right arrow Articles by Kelly, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pitman, A. G.
Right arrow Articles by Kelly, M. J.
Journal of Nuclear Medicine Vol. 43 No. 9 1259-1267
© 2002 by Society of Nuclear Medicine


Basic Science Investigations

Effect of Mechanically Simulated Diaphragmatic Respiratory Motion on Myocardial SPECT Processed With and Without Attenuation Correction

Alexander G. Pitman, BMedSci, MBBS1, Victor Kalff, BMedSci, MBBS1, Bruce Van Every, BAppSci1, Borghild Risa, BAppSci1, Leighton R. Barnden, PhD2 and Michael J. Kelly, MBBS1

1 Department of Nuclear Medicine, The Alfred Hospital, Prahran, Victoria, Australia
2 Department of Nuclear Medicine, The Queen Elizabeth Hospital, Woodville, South Australia, Australia

The goal of this study was to assess the effect of diaphragmatic respiratory motion on inferior wall cold artifact in myocardial SPECT and to assess the ability of attenuation correction (AC) to correct for this artifact in the presence of diaphragmatic motion. Methods: We used an anthropomorphic phantom with ventricular wall activity, variable ventricular caudal tilt, attenuating liver and spleen cold inserts, and variable vertical (diaphragmatic) motion amplitude and pattern. Cardiac SPECT images were acquired on a gamma camera with dual scanning transmission line sources and commercially available AC software (with scatter correction and iterative reconstruction). The acquired data were processed either using filtered backprojection or with the AC software. The resulting myocardial activity maps were processed with polar plots and with standardized inferior-to-anterior and anterior-to-lateral wall ratios. Results: Subdiaphragmatic attenuation reduces inferior wall counts and this component of inferior wall artifact is fully corrected by AC relative to anterior wall counts both with and without diaphragmatic respiratory motion. In the phantom, diaphragmatic motion artifact manifests as reduction in relative count density in both the anterior wall and the inferior wall relative to the lateral wall, which is not corrected by AC. This artifact becomes more marked with increasing respiratory amplitude and its symmetry depends on the pattern of diaphragmatic motion. Conclusion: Images with AC acquired at small respiratory amplitudes (~2 cm) in the phantom resemble images with AC found in published normal patient databases. These results support a clinical need for respiratory gating of myocardial SPECT images.

Key Words: respiratory motion artifact • diaphragmatic motion artifact • myocardial SPECT • inferior wall artifact • attenuation correction




This article has been cited by other articles:


Home page
JNMHome page
G. Kovalski, O. Israel, Z. Keidar, A. Frenkel, J. Sachs, and H. Azhari
Correction of Heart Motion Due to Respiration in Clinical Myocardial Perfusion SPECT Scans Using Respiratory Gating
J. Nucl. Med., April 1, 2007; 48(4): 630 - 636.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Fricke, E. Fricke, R. Weise, A. Kammeier, O. Lindner, and W. Burchert
A Method to Remove Artifacts in Attenuation-Corrected Myocardial Perfusion SPECT Introduced by Misalignment Between Emission Scan and CT-Derived Attenuation Maps
J. Nucl. Med., October 1, 2004; 45(10): 1619 - 1625.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. V. Narayanan, M. A. King, P. H. Pretorius, S. T. Dahlberg, F. Spencer, E. Simon, E. Ewald, E. Healy, K. MacNaught, and J. A. Leppo
Human-Observer Receiver-Operating-Characteristic Evaluation of Attenuation, Scatter, and Resolution Compensation Strategies for 99mTc Myocardial Perfusion Imaging
J. Nucl. Med., November 1, 2003; 44(11): 1725 - 1734.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2002 by the Society of Nuclear Medicine.