JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Skalski, J.
Right arrow Articles by Meyer, C. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Skalski, J.
Right arrow Articles by Meyer, C. R.
Journal of Nuclear Medicine Vol. 43 No. 9 1184-1187
© 2002 by Society of Nuclear Medicine


Clinical Investigations

Comparison of Mutual Information-Based Warping Accuracy for Fusing Body CT and PET by 2 Methods: CT Mapped onto PET Emission Scan Versus CT Mapped onto PET Transmission Scan

Joseph Skalski1, Richard L. Wahl, MD1 and Charles R. Meyer, PhD2

1 Department of Nuclear Medicine and Radiology, Johns Hopkins University, Baltimore, Maryland
2 Department of Radiology, University of Michigan Medical Center, Ann Arbor, Michigan

This article assesses the resulting accuracies of 2 registration methods using the same multimodal mutual information registration algorithm. In the indirect, fusion method, the CT dataset is warped onto the PET transmission scan, and then the patient’s attenuation-corrected emission dataset is substituted for the transmission dataset. In the direct, fusion method, the CT is warped directly onto the attenuation-corrected emission dataset. Methods: CT and 18F-FDG PET image datasets from 14 subjects with malignant lesions in the thorax were registered. In both CT and PET imaging acquisitions, the patient’s arms were at the patient’s side, resting on the scanning couch in a manner similar to that of routine PET acquisition procedures. The accuracy of the 2 warping registrations was assessed by measuring the distance between lesion centroids on CT and PET emission after fusion. Results: The indirect method has a statistically smaller mean error, 6.2 mm, than the direct method, 10.6 mm. Conclusion: The indirect method appears to be the more accurate/reliable choice for fusing body CT and FDG PET.

Key Words: registration • fusion • mutual information • CT • PET • emission • transmission • lesion centroids




This article has been cited by other articles:


Home page
JNMHome page
R. Shekhar, V. Walimbe, S. Raja, V. Zagrodsky, M. Kanvinde, G. Wu, and B. Bybel
Automated 3-Dimensional Elastic Registration of Whole-Body PET and CT from Separate or Combined Scanners
J. Nucl. Med., September 1, 2005; 46(9): 1488 - 1496.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J.-H. Kim, J. Czernin, M. S. Allen-Auerbach, B. S. Halpern, B. J. Fueger, J. R. Hecht, O. Ratib, M. E. Phelps, and W. A. Weber
Comparison Between 18F-FDG PET, In-Line PET/CT, and Software Fusion for Restaging of Recurrent Colorectal Cancer
J. Nucl. Med., April 1, 2005; 46(4): 587 - 595.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. V. Vogel, W. J.G. Oyen, J. O. Barentsz, J. H.A.M. Kaanders, and F. H.M. Corstens
PET/CT: Panacea, Redundancy, or Something in Between?
J. Nucl. Med., January 1, 2004; 45(90010): 15S - 24.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. J. Slomka
Software Approach to Merging Molecular with Anatomic Information
J. Nucl. Med., January 1, 2004; 45(90010): 36S - 45.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. J. Slomka, D. Dey, C. Przetak, U. E. Aladl, and R. P. Baum
Automated 3-Dimensional Registration of Stand-Alone 18F-FDG Whole-Body PET with CT
J. Nucl. Med., July 1, 2003; 44(7): 1156 - 1167.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2002 by the Society of Nuclear Medicine.