JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Richard, J.-C.
Right arrow Articles by Guérin, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Richard, J.-C.
Right arrow Articles by Guérin, C.
Journal of Nuclear Medicine Vol. 43 No. 8 1063-1071
© 2002 by Society of Nuclear Medicine


Basic Science Investigations

Comparison of PET with Radioactive Microspheres to Assess Pulmonary Blood Flow

Jean-Christophe Richard, MD1, Marc Janier, MD2, Francois Decailliot, MD1, Didier Le Bars, PhD2, Franck Lavenne2, Veronique Berthier2, Martine Lionnet2, Luc Cinotti, MD2, Guy Annat, MD1 and Claude Guérin, MD1,3

1 Équipe d’Accueil 1896, Université Claude Bernard Lyon I, Lyon, France
2 Centre d’Etudes et de Recherche Médicales par Tomographie d’Emission de Positrons, Hôpital Neuro-Cardiologique, Lyon, France
3 Service de Réanimation Médicale et Assistance Respiratoire, Lyon, France

Microsphere technique is the reference for assessment of pulmonary blood flow (PBF) but is destructive; PET, however, can determine PBF noninvasively. Comparisons of these 2 methods are scanty. Our study aimed at comparing these 2 techniques using a mathematic model taking into account the right ventricle in determining the transit time of a tracer through lung tissue. Methods: Ten normal pigs were investigated at baseline, during dobutamine infusion, and during 10 cm H2O of positive end-expiratory pressure. Under each condition, PBF was successively measured with PET (PET-PBF) and radioactive microspheres (MS-PBF). For PET-PBF, 2 mCi (74 MBq) 15O-labeled water were injected intravenously over 20 s and PET scanning was performed for 10 min. The input function was determined noninvasively from PET and invasively from mixed venous blood withdrawals. PET-PBF was computed using a mathematic model taking into account the right ventricle in determining the transit time of the tracer through lung tissue. For MS-PBF, 1 given isotope was injected under a given condition. PET-PBF and MS-PBF for 5 lung regions were compared. Results: PET-PBF significantly correlated with MS-PBF both over all experimental points (PET-PBF = 0.79 · MS-PBF + 1,538; r = 0.79; P < 0.001) and in separate lung regions. Invasive and noninvasive input functions also correlated significantly (r = 0.90; P < 0.001). Simulations stressed the crucial role of the right ventricle to the transit time of tracer through lung tissue in the determination of PET-PBF. Conclusion: PBF can accurately be assessed using PET and a mathematic model taking into account the right ventricle in determining the transit time of a tracer through lung tissue. Noninvasive determination of the input function of the right ventricle is accurate and can readily be used for clinical applications.

Key Words: PET • lung imaging technique • regional pulmonary blood flow • pig




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
T. Richter, R. Bergmann, J. Pietzsch, I. Kozle, F. Hofheinz, E. Schiller, M. Ragaller, and J. van den Hoff
Effects of posture on regional pulmonary blood flow in rats as measured by PET
J Appl Physiol, February 1, 2010; 108(2): 422 - 429.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
A. J. de Langen, V. E. M. van den Boogaart, J. T. Marcus, and M. Lubberink
Use of H215O-PET and DCE-MRI to Measure Tumor Blood Flow
Oncologist, June 1, 2008; 13(6): 631 - 644.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. S. Harris and D. P. Schuster
Visualizing lung function with positron emission tomography
J Appl Physiol, January 1, 2007; 102(1): 448 - 458.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. C. Richard, M. Janier, F. Lavenne, V. Berthier, D. Lebars, G. Annat, F. Decailliot, and C. Guerin
Effect of position, nitric oxide, and almitrine on lung perfusion in a porcine model of acute lung injury
J Appl Physiol, December 1, 2002; 93(6): 2181 - 2191.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2002 by the Society of Nuclear Medicine.