JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nuyts, J.
Right arrow Articles by Mortelmans, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nuyts, J.
Right arrow Articles by Mortelmans, L.
Journal of Nuclear Medicine Vol. 43 No. 8 1054-1062
© 2002 by Society of Nuclear Medicine


Basic Science Investigations

Reducing Loss of Image Quality Because of the Attenuation Artifact in Uncorrected PET Whole-Body Images

Johan Nuyts, PhD1, Sigrid Stroobants, MD1, Patrick Dupont, PhD1, Stefaan Vleugels, MSc1, Patrick Flamen, MD, PhD1 and Luc Mortelmans, MD, PhD1

1 Nuclear Medicine, Katholieke Universiteit Leuven, Leuven, Belgium

In whole-body PET, it is not unusual to shorten the study time by omitting the transmission scan and to ignore attenuation during reconstruction. If a transmission scan is available, many centers reconstruct the images with, but also without, attenuation correction. Although ignoring attenuation leads to an artifact in the reconstructed images, these images still provide valuable diagnostic information in oncologic applications. Several authors have reported that the attenuation artifact may actually increase the tumor-to-background ratio. In this study, we analyzed the causes of the artifact and proposed a new algorithm to reduce the adverse effects on visual image quality. Methods: We analyzed the causes of the attenuation artifact mathematically and numerically, and we examined its effect on tumor-to-background ratio and on signal-to-noise ratio. In addition, we showed that the attenuation artifact may lead to loss of image detail in conventional maximum-likelihood expectation maximization (MLEM) reconstruction. A new maximum-likelihood algorithm allowing negative reconstruction values (NEG-ML) was derived to reduce this loss. Results: The attenuation artifact consists of 2 components. The first component is the well-known scaling effect: The apparent activity is reduced because attenuation decreases the fraction of detected photons. The second component is a relatively smooth negative contribution that is added to attenuated regions surrounded by activity. The second component tends to increase the tumor-to-background ratio. However, a simulation experiment shows that this increase in signal may be entirely offset by an increase in noise. The negative contribution can interfere with the nonnegativity constraint of the MLEM algorithm, leading to loss of image detail in regions of high attenuation. The new NEG-ML algorithm avoids the problem by allowing negative pixel values. The algorithm is similar to MLEM in the suppression of the streak artifact but provides more anatomic information. In our department, it is in routine clinical use for reconstruction of PET whole-body images without attenuation correction. Conclusion: Ignoring attenuation may increase the tumor-to-background ratio, but this increase does not imply improved tumor detection. The NEG-ML algorithm reduces the adverse effect of the attenuation artifact on visual image quality.

Key Words: PET • attenuation correction • iterative reconstruction • contrast • tumor-to-background ratio




This article has been cited by other articles:


Home page
JNMHome page
R.-F. Yen, R.-L. Hong, K.-Y. Tzen, M.-H. Pan, and T. H.-H. Chen
Whole-Body 18F-FDG PET in Recurrent or Metastatic Nasopharyngeal Carcinoma
J. Nucl. Med., May 1, 2005; 46(5): 770 - 774.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Bai, P. E. Kinahan, D. Brasse, C. Comtat, D. W. Townsend, C. C. Meltzer, V. Villemagne, M. Charron, and M. Defrise
An Analytic Study of the Effects of Attenuation on Tumor Detection in Whole-Body PET Oncology Imaging
J. Nucl. Med., November 1, 2003; 44(11): 1855 - 1861.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2002 by the Society of Nuclear Medicine.