Basic Science Investigations |
Department of Radiology, University of Arizona Health Sciences Center, Tucson, Arizona
The purpose of this study was to develop an in vivo imaging protocol for a high-resolution stationary SPECT system, called FASTSPECT, in a rat heart model of ischemia-reperfusion (IR) and to compare 99mTc-sestamibi imaging and triphenyltetrazolium chloride (TTC) staining for reliability and accuracy in the measurement of myocardial infarcts. Methods: FASTSPECT consists of 24 modular cameras and a 24-pinhole aperture with 1.5-mm spatial resolution and 13.3 cps/µCi (0.359 cps/kBq) sensitivity. The IR heart model was created by ligating the left coronary artery for 90 min and then releasing the ligature for 30 min. Two hours after 99mTc-sestamibi injection (510 mCi [185370 MBq]), images were acquired for 510 min for 5 control rats and 11 IR rats. The hearts were excised, and the left ventricle was sectioned into 4 slices for TTC staining. Results: Left and right ventricular myocardium in control rats was shown clearly, with uniform 99mTc-sestamibi distribution and 100% TTC staining for viable myocardium. Nine of 11 rats with IR survived throughout imaging and exhibited 50.8% ± 2.7% ischemic area and 37.9% ± 3.9% infarct in the left ventricle on TTC staining. The infarct size measured by FASTSPECT imaging was 37.6% ± 3.6%, which correlated significantly with that measured by TTC staining (r = 0.974; P < 0.01). Conclusion: The results confirmed the accuracy of FASTSPECT imaging for measurement of acute myocardial infarcts in rat hearts. Application of FASTSPECT imaging in small animals may be feasible for investigating myocardial IR injury and the effects of revascularization.
Key Words: high-resolution SPECT 99mTc-sestamibi myocardial infarction ischemia-reperfusion
This article has been cited by other articles:
![]() |
B. M.W. Tsui and D. L. Kraitchman Recent Advances in Small-Animal Cardiovascular Imaging J. Nucl. Med., May 1, 2009; 50(5): 667 - 670. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. van der Have, B. Vastenhouw, R. M. Ramakers, W. Branderhorst, J. O. Krah, C. Ji, S. G. Staelens, and F. J. Beekman U-SPECT-II: An Ultra-High-Resolution Device for Molecular Small-Animal Imaging J. Nucl. Med., April 1, 2009; 50(4): 599 - 605. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. M. Sherif, A. Saraste, E. Weidl, A. W. Weber, T. Higuchi, S. Reder, T. Poethko, G. Henriksen, D. Casebier, S. Robinson, et al. Evaluation of a Novel 18F-Labeled Positron-Emission Tomography Perfusion Tracer for the Assessment of Myocardial Infarct Size in Rats Circ Cardiovasc Imaging, March 1, 2009; 2(2): 77 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Tran, P. R. Franken, F. Maskali, J. Nloga, P. Maureira, S. Poussier, F. Groubatch, C. Vanhove, J.-P. Villemot, and P.-Y. Marie Intramyocardial Implantation of Bone Marrow-Derived Stem Cells Enhances Perfusion in Chronic Myocardial Infarction: Dependency on Initial Perfusion Depth and Follow-up Assessed by Gated Pinhole SPECT J. Nucl. Med., March 1, 2007; 48(3): 405 - 412. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Vastenhouw and F. Beekman Submillimeter Total-Body Murine Imaging with U-SPECT-I J. Nucl. Med., March 1, 2007; 48(3): 487 - 493. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Zhou, P. D. Acton, and V. A. Ferrari Imaging Stem Cells Implanted in Infarcted Myocardium J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2094 - 2106. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Stegger, A.-N. Hoffmeier, K. P. Schafers, S. Hermann, O. Schober, M. A. Schafers, and G. Theilmeier Accurate Noninvasive Measurement of Infarct Size in Mice with High-Resolution PET J. Nucl. Med., November 1, 2006; 47(11): 1837 - 1844. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. McVeigh Emerging Imaging Techniques Circ. Res., April 14, 2006; 98(7): 879 - 886. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Maskali, P. R. Franken, S. Poussier, N. Tran, C. Vanhove, H. Boutley, H. Le Gall, G. Karcher, F. Zannad, P. Lacolley, et al. Initial Infarct Size Predicts Subsequent Cardiac Remodeling in the Rat Infarct Model: An In Vivo Serial Pinhole Gated SPECT Study J. Nucl. Med., February 1, 2006; 47(2): 337 - 344. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Beekman, F. van der Have, B. Vastenhouw, A. J.A. van der Linden, P. P. van Rijk, J. P. H. Burbach, and M. P. Smidt U-SPECT-I: A Novel System for Submillimeter-Resolution Tomography with Radiolabeled Molecules in Mice J. Nucl. Med., July 1, 2005; 46(7): 1194 - 1200. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Dawson, C. A. Lygate, J. Saunders, J. E. Schneider, X. Ye, K. Hulbert, J. A. Noble, and S. Neubauer Quantitative 3-Dimensional Echocardiography for Accurate and Rapid Cardiac Phenotype Characterization in Mice Circulation, September 21, 2004; 110(12): 1632 - 1637. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. Liu, H. H. Barrett, G. D. Stevenson, G. A. Kastis, M. Bettan, L. R. Furenlid, D. W. Wilson, and K. Y. Pak High-Resolution Imaging with 99mTc-Glucarate for Assessing Myocardial Injury in Rat Heart Models Exposed to Different Durations of Ischemia with Reperfusion J. Nucl. Med., July 1, 2004; 45(7): 1251 - 1259. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. C. Wu, D.-W. Gao, R. E. Sievers, R. J. Lee, B. H. Hasegawa, and M. W. Dae Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice J. Am. Coll. Cardiol., August 6, 2003; 42(3): 576 - 582. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |