JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Blagosklonov, O.
Right arrow Articles by Cardot, J.-C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Blagosklonov, O.
Right arrow Articles by Cardot, J.-C.
Journal of Nuclear Medicine Vol. 43 No. 3 285-291
© 2002 by Society of Nuclear Medicine


Clinical Investigations

Poststress Motionlike Artifacts Caused by the Use of a Dual-Head Gamma Camera for 201Tl Myocardial SPECT

Oleg Blagosklonov, MD;1, Ahmad Sabbah, MD;1, Josette Verdenet, PhD;1, Michel Baud, PhD;1 and Jean-Claude Cardot, MD, PhD1

1 Department of Nuclear Cardiology, Jean Minjoz University Hospital, Besançon, France

When performing 201Tl myocardial SPECT using a dual-head gamma camera on patients after exercise stress, we have observed in some a sudden increase in the counting rate between the 16th and 17th images. This increase provoked motionlike artifacts, which increased the number of false-positive findings. The aim of our study was to determine possible causes for this leap in activity. Methods: We performed myocardial SPECT using a dual-head gamma camera on 110 patients after exercise stress: in 38 patients approximately 5 min after injection (group 1), in 43 patients approximately 14 min after injection (group 2), and in 29 patients twice, at approximately 5 and 20 min after injection (group 3). We also performed dynamic data acquisition for 10 min on 18 patients after exercise stress. We compared activity in the heart region in image series obtained after exercise stress and at rest. Results: Daily quality control tests eliminated the possibility of any malfunctions of the gamma camera. Careful image analysis showed no visible patient motion. Our results showed that upward creep of the heart could not be a cause of the described phenomenon. After exercise stress, a >=5% activity leap in the heart region on the 16th and 17th frames was more frequent in group 1 than in group 2. Two consecutive acquisitions after exercise stress showed that the leap was >5% in 24 patients (83%) and 12 patients (41%) at the first and second acquisitions, respectively (group 3). In all patients, the leap was <5% at rest. Dynamic studies showed that the activity in the heart region steadily decreased in all patients after exercise stress. We suggest that decreasing 201Tl concentrations in myocardium or blood could be a major reason for the described artifacts. Conclusion: We proposed that the pharmacokinetics of 201Tl-chloride be evaluated within a short time after injection in humans after exercise stress. Now, in our department, we have begun acquisition approximately 12 min after 201Tl administration, and the above-mentioned phenomenon has not appeared. However, to avoid the artifacts caused by early redistribution of 201Tl, acquisition must not begin too late.

Key Words: myocardial SPECT • quality control • SPECT artifacts • dual-head gamma camera




This article has been cited by other articles:


Home page
RadiologyHome page
J. K. Min, N. Kang, L. J. Shaw, R. B. Devereux, M. Robinson, F. Lin, A. P. Legorreta, and A. Gilmore
Costs and Clinical Outcomes after Coronary Multidetector CT Angiography in Patients without Known Coronary Artery Disease: Comparison to Myocardial Perfusion SPECT1
Radiology, October 1, 2008; 249(1): 62 - 70.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
A. O. Karacalioglu, B. Jata, S. Kilic, N. Arslan, S. Ilgan, and M. A. Ozguven
A Physiologic Approach to Decreasing Upward Creep of the Heart During Myocardial Perfusion Imaging
J. Nucl. Med. Technol., December 1, 2006; 34(4): 215 - 219.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. Kirch, J. Koss, T. Bublitz, and P. Steele
False-Positive Findings on Myocardial Perfusion SPECT
J. Nucl. Med., September 1, 2004; 45(9): 1597 - 1597.
[Full Text] [PDF]


Home page
JNMHome page
D. Kirch, J. Koss, P. Steele, and T. Bublitz
Effect of Acquisition Orbit on SPECT in Phantoms
J. Nucl. Med., June 1, 2003; 44(6): 993 - 995.
[Full Text]


Home page
JNMHome page
D. Kirch, P. Steele, J. Koss, T. Bublitz, O. Blagosklonov, L. Comas, A. Sabbah, J. Verdenet, M. Baud, and J.-C. Cardot
Motionlike Artifacts in Myocardial SPECT
J. Nucl. Med., March 1, 2003; 44(3): 484 - 486.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2002 by the Society of Nuclear Medicine.