JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, J. S.
Right arrow Articles by Lee, M. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, J. S.
Right arrow Articles by Lee, M. C.
Journal of Nuclear Medicine Vol. 42 No. 6 938-943
© 2001 by Society of Nuclear Medicine


BASIC SCIENCE INVESTIGATIONS

Blind Separation of Cardiac Components and Extraction of Input Function from H215O Dynamic Myocardial PET Using Independent Component Analysis

Jae Sung Lee, Dong Soo Lee, Ji Young Ahn, Gi Jeong Cheon, Seok-Ki Kim, Jeong Seok Yeo, Kangjun Seo, Kwang Suk Park, June-Key Chung and Myung Chul Lee

Departments of Nuclear Medicine and Biomedical Engineering, Seoul National University College of Medicine, Seoul, Korea

The independent component analysis (ICA) method is suggested to be useful for separation of the ventricles and the myocardium and for extraction of the left ventricular input function from the dynamic H215O myocardial PET. The ICA-generated input function was validated with the sampling method, and the myocardial blood flow (MBF) calculated with this input function was compared with the microsphere results. Methods: We assumed that the elementary activities of the ventricular pools and the myocardium were spatially independent and that the mixture of them composed dynamic PET image frames. The independent components were estimated by recursively minimizing the mutual information (measure of dependence) between the components. The ICA-generated input functions were compared with invasively derived arterial blood samples. Moreover, the regional MBF calculated using the ICA-generated input functions and single-compartment model was correlated with the results obtained from the radiolabeled microspheres. Results: The ventricles and the myocardium were successfully separated in all cases within a short computation time (<15 s). The ICA-generated input functions displayed shapes similar to those obtained by arterial sampling except that they had a smoother tail than those obtained by sampling, which meant that ICA removed the statistical noise from the time–activity curves. The ICA-generated input function showed a longer time delay of peaks than those obtained by arterial sampling. MBFs estimated using the ICA-generated input functions ranged from 1.10 to approximately 2.52 mL/min/g at rest and from 1.69 to approximately 8.00 mL/min/g after stress and correlated well with those calculated with microspheres (y = 0.45 + 0.98x; r = 0.95, P < 0.000). Conclusion: ICA, a rapid and reliable method for extraction of the pure physiologic components, was a valid and useful method for quantification of the regional MBF using H215O PET.

Key Words: PET • independent component analysis • myocardial blood flow




This article has been cited by other articles:


Home page
JNMHome page
J. S. Lee, D. S. Lee, J. Y. Ahn, J. S. Yeo, G. J. Cheon, S.-K. Kim, K. S. Park, J.-K. Chung, and M. C. Lee
Generation of Parametric Image of Regional Myocardial Blood Flow Using H215O Dynamic PET and a Linear Least-Squares Method