JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Votaw, J. R.
Right arrow Articles by White, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Votaw, J. R.
Right arrow Articles by White, M.
Journal of Nuclear Medicine Vol. 42 No. 5 701-706
© 2001 by Society of Nuclear Medicine


CLINICAL INVESTIGATIONS

Comparison of 2-Dimensional and 3-Dimensional Cardiac 82Rb PET Studies

John R. Votaw and Michael White

Department of Radiology, Emory University School of Medicine, Atlanta, Georgia

Most new PET scanners have the capability to collect data in 3-dimensional (3D) (septa removed) mode. This allows many more detected events at the cost of increased random events and scatter. In the case of 82Rb imaging, the injected dose might have to be limited to avoid saturating the scanner. We present a comparison of 2-dimensional (2D) and 3D data collection for 82Rb cardiac studies using the ECAT EXACT scanner. Methods: Resting 82Rb cardiac studies were collected in 2D and 3D modes for 33 consecutive patients. Four experienced physicians rated the images to determine if the different acquisition methods would lead to different patient care. A separate quantitative analysis was performed on data from multiple scans of a thoracic phantom filled to simulate cardiac and background radioactivity corresponding to 82Rb injections between 37 and 1740 MBq. Results: The 2D and 3D studies were significantly different, with the image quality being poorer in the 3D studies. The scanner collected data at near its maximal counting rate for either 1480-MBq 2D or 37-MBq 3D acquisitions. Because the data collection was counting rate limited in either mode, and there are more random and scatter events in 3D mode, the 2D acquisitions resulted in more detected true events and a better signal-to-noise ratio. Conclusion: Cardiac 82Rb studies should be performed in 2D mode when using the ECAT EXACT scanner.

Key Words: 2D PET • 3D PET • 82Rb • heart




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
B. Sanghera, G. Lowe, D. Wellstead, J. Lowe, J. Chambers, and W. Wong
Scan-Time Reduction Using Noise-Matched Images in 2- and 3-Dimensional Bismuth Germanate PET/CT: Clinical Study in Head and Neck Cancer
J. Nucl. Med. Technol., June 1, 2009; 37(2): 74 - 82.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Ibaraki, S. Miura, E. Shimosegawa, S. Sugawara, T. Mizuta, A. Ishikawa, and M. Amano
Quantification of Cerebral Blood Flow and Oxygen Metabolism with 3-Dimensional PET and 15O: Validation by Comparison with 2-Dimensional PET
J. Nucl. Med., January 1, 2008; 49(1): 50 - 59.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Schepis, O. Gaemperli, V. Treyer, I. Valenta, C. Burger, P. Koepfli, M. Namdar, I. Adachi, H. Alkadhi, and P. A. Kaufmann
Absolute Quantification of Myocardial Blood Flow with 13N-Ammonia and 3-Dimensional PET
J. Nucl. Med., November 1, 2007; 48(11): 1783 - 1789.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. A. Lodge, R. D. Badawi, R. Gilbert, P. E. Dibos, and B. R. Line
Comparison of 2-Dimensional and 3-Dimensional Acquisition for 18F-FDG PET Oncology Studies Performed on an LSO-Based Scanner
J. Nucl. Med., January 1, 2006; 47(1): 23 - 31.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Schwaiger, S. Ziegler, and S. G. Nekolla
PET/CT: Challenge for Nuclear Cardiology
J. Nucl. Med., October 1, 2005; 46(10): 1664 - 1678.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Brogsitter, T. Gruning, R. Weise, P. Wielepp, O. Lindner, R. Korfer, and W. Burchert
18F-FDG PET for Detecting Myocardial Viability: Validation of 3D Data Acquisition
J. Nucl. Med., January 1, 2005; 46(1): 19 - 24.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Lubberink, R. Boellaard, A. P. van der Weerdt, F. C. Visser, and A. A. Lammertsma
Quantitative Comparison of Analytic and Iterative Reconstruction Methods in 2- and 3-Dimensional Dynamic Cardiac 18F-FDG PET
J. Nucl. Med., December 1, 2004; 45(12): 2008 - 2015.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Knesaurek, J. Machac, B. R. Krynyckyi, and O. D. Almeida
Comparison of 2-Dimensional and 3-Dimensional 82Rb Myocardial Perfusion PET Imaging
J. Nucl. Med., August 1, 2003; 44(8): 1350 - 1356.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Knesaurek
New Developments in PET Instrumentation: Quo Vadis PET?
J. Nucl. Med., December 1, 2001; 42(12): 1831 - 1832.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.