JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mankoff, D. A.
Right arrow Articles by Krohn, K. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mankoff, D. A.
Right arrow Articles by Krohn, K. A.
Journal of Nuclear Medicine Vol. 42 No. 4 679-684
© 2001 by Society of Nuclear Medicine


BASIC SCIENCE INVESTIGATIONS

[18F]Fluoroestradiol Radiation Dosimetry in Human PET Studies

David A. Mankoff, Lanell M. Peterson, Timothy J. Tewson, Jeanne M. Link, Julie R. Gralow, Michael M. Graham and Kenneth A. Krohn

Departments of Radiology and Medical Oncology, University of Washington School of Medicine, Seattle, Washington

[18F]16{alpha}-fluoroestradiol (FES) is a PET imaging agent useful for the study of estrogen receptors in breast cancer. We estimated the radiation dosimetry for this tracer using data obtained in patient studies. Methods: Time-dependent tissue concentrations of radioactivity were determined from blood samples and PET images in 49 patients (52 studies) after intravenous injection of FES. Radiation absorbed doses were calculated using the procedures of the MIRD committee, taking into account the variation in dose based on the distribution of activities observed in the individual patients. Effective dose equivalent was calculated using International Commission on Radiological Protection Publication 60 weights for the standard woman. Results: The effective dose equivalent was 0.022 mSv/MBq (80 mrem/mCi). The organ that received the highest dose was the liver (0.13 mGy/MBq [470 mrad/mCi]), followed by the gallbladder (0.10 mGy/MBq [380 mrad/mCi]) and the urinary bladder (0.05 mGy/MBq [190 mrad/mCi]). Conclusion: The organ doses are comparable to those associated with other commonly performed nuclear medicine tests. FES is a useful estrogen receptor-imaging agent, and the potential radiation risks associated with this study are well within accepted limits.

Key Words: PET • estrogen receptor • fluoroestradiol • dosimetry




This article has been cited by other articles:


Home page
JNMHome page
D. A. Mankoff, J. M. Link, H. M. Linden, L. Sundararajan, and K. A. Krohn
Tumor Receptor Imaging
J. Nucl. Med., June 1, 2008; 49(Suppl_2): 149S - 163S.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Van Laere, M. Koole, S. M. Sanabria Bohorquez, K. Goffin, I. Guenther, M. J. Belanger, J. Cote, P. Rothenberg, I. De Lepeleire, I. D. Grachev, et al.
Whole-Body Biodistribution and Radiation Dosimetry of the Human Cannabinoid Type-1 Receptor Ligand 18F-MK-9470 in Healthy Subjects
J. Nucl. Med., March 1, 2008; 49(3): 439 - 445.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
D. A. Mankoff, J. F. Eary, J. M. Link, M. Muzi, J. G. Rajendran, A. M. Spence, and K. A. Krohn
Tumor-Specific Positron Emission Tomography Imaging in Patients: [18F] Fluorodeoxyglucose and Beyond
Clin. Cancer Res., June 15, 2007; 13(12): 3460 - 3469.
[Abstract] [Full Text] [PDF]


Home page
JCOHome page
H. M. Linden, S. A. Stekhova, J. M. Link, J. R. Gralow, R. B. Livingston, G. K. Ellis, P. H. Petra, L. M. Peterson, E. K. Schubert, L. K. Dunnwald, et al.
Quantitative Fluoroestradiol Positron Emission Tomography Imaging Predicts Response to Endocrine Treatment in Breast Cancer
J. Clin. Oncol., June 20, 2006; 24(18): 2793 - 2799.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
L. M. Cher, C. Murone, N. Lawrentschuk, S. Ramdave, A. Papenfuss, A. Hannah, G. J. O'Keefe, J. I. Sachinidis, S. U. Berlangieri, G. Fabinyi, et al.
Correlation of Hypoxic Cell Fraction and Angiogenesis with Glucose Metabolic Rate in Gliomas Using 18F-Fluoromisonidazole, 18F-FDG PET, and Immunohistochemical Studies
J. Nucl. Med., March 1, 2006; 47(3): 410 - 418.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Vesselle, J. Grierson, L. M. Peterson, M. Muzi, D. A. Mankoff, and K. A. Krohn
18F-Fluorothymidine Radiation Dosimetry in Human PET Imaging Studies
J. Nucl. Med., September 1, 2003; 44(9): 1482 - 1488.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.