BASIC SCIENCE INVESTIGATIONS |
Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, São Paulo; and Universidade Federal de Pernambuco, Recife, Brazil
This study was intended to verify the capability of the Monte Carlo MCNP-4B code to evaluate spatial dose distribution based on information gathered from CT or SPECT. Methods: A new three-dimensional (3D) dose calculation approach for internal emitter use in radioimmunotherapy (RIT) was developed using the Monte Carlo MCNP-4B code as the photon and electron transport engine. It was shown that the MCNP-4B computer code can be used with voxel-based anatomic and physiologic data to provide 3D dose distributions. Results: This study showed that the MCNP-4B code can be used to develop a treatment planning system that will provide such information in a time manner, if dose reporting is suitably optimized. If each organ is divided into small regions where the average energy deposition is calculated with a typical volume of 0.4 cm3, regional dose distributions can be provided with reasonable central processing unit times (on the order of 1224 h on a 200-MHz personal computer or modest workstation). Further efforts to provide semiautomated region identification (segmentation) and improvement of marrow dose calculations are needed to supply a complete system for RIT. It is envisioned that all such efforts will continue to develop and that internal dose calculations may soon be brought to a similar level of accuracy, detail, and robustness as is commonly expected in external dose treatment planning. Conclusion: For this study we developed a code with a user-friendly interface that works on several nuclear medicine imaging platforms and provides timely patient-specific dose information to the physician and medical physicist. Future therapy with internal emitters should use a 3D dose calculation approach, which represents a significant advance over dose information provided by the standard geometric phantoms used for more than 20 y (which permit reporting of only average organ doses for certain standardized individuals)
Key Words: radioimmunotherapy patient-specific dosimetry Monte Carlo simulation electrons and photons
This article has been cited by other articles:
![]() |
J. M. G. Ros, M. Moraleda, M. A. Lopez, T. Navarro, and J. F. Navarro Monte Carlo based voxel phantoms for in vivo internal dosimetry Radiat Prot Dosimetry, July 1, 2007; 125(1-4): 161 - 165. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Lee, S. Park, and J. K. Lee Specific absorbed fraction for korean adult voxel phantom from internal photon source Radiat Prot Dosimetry, February 1, 2007; 123(3): 360 - 368. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Song, B. He, A. Prideaux, Y. Du, E. Frey, W. Kasecamp, P. W. Ladenson, R. L. Wahl, and G. Sgouros Lung Dosimetry for Radioiodine Treatment Planning in the Case of Diffuse Lung Metastases J. Nucl. Med., December 1, 2006; 47(12): 1985 - 1994. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Kim, J. H. Whang, and C. S. Kim Paired-organ and other selected absorbed fraction for the Korean Reference Adult Male model Radiat Prot Dosimetry, July 1, 2006; 118(4): 395 - 401. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. G. Stabin, T. E. Peterson, G. E. Holburn, and M. A. Emmons Voxel-Based Mouse and Rat Models for Internal Dose Calculations J. Nucl. Med., April 1, 2006; 47(4): 655 - 659. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Van Riper A CT and MRI scan to MCNP input conversion program Radiat Prot Dosimetry, December 20, 2005; 115(1-4): 513 - 516. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Chiavassa, A. Lemosquet, I. Aubineau-Laniece, L. de Carlan, I. Clairand, L. Ferrer, M. Bardies, D. Franck, and M. Zankl Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources Radiat Prot Dosimetry, December 20, 2005; 116(1-4): 631 - 635. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. K. Dewaraja, S. J. Wilderman, M. Ljungberg, K. F. Koral, K. Zasadny, and M. S. Kaminiski Accurate Dosimetry in 131I Radionuclide Therapy Using Patient-Specific, 3-Dimensional Methods for SPECT Reconstruction and Absorbed Dose Calculation J. Nucl. Med., May 1, 2005; 46(5): 840 - 849. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Sgouros Dosimetry of Internal Emitters J. Nucl. Med., January 1, 2005; 46(1_suppl): 18S - 27S. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Ljungberg, K. Sjogreen, X. Liu, E. Frey, Y. Dewaraja, and S.-E. Strand A 3-Dimensional Absorbed Dose Calculation Method Based on Quantitative SPECT for Radionuclide Therapy: Evaluation for 131I Using Monte Carlo Simulation J. Nucl. Med., August 1, 2002; 43(8): 1101 - 1109. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |