JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Weinzapfel, B. T.
Right arrow Articles by Hutchins, G. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Weinzapfel, B. T.
Right arrow Articles by Hutchins, G. D.
Journal of Nuclear Medicine Vol. 42 No. 3 483-491
© 2001 by Society of Nuclear Medicine


BASIC SCIENCE INVESTIGATIONS

Automated PET Attenuation Correction Model for Functional Brain Imaging

Brett T. Weinzapfel and Gary D. Hutchins

Department of Physiology and Biophysics and Imaging Science Division, Department of Radiology, Indiana University School of Medicine, Indianapolis, Indiana

The failure to compensate for subject motion between attenuation correction scans and emission scans precludes the optimization of functional brain imaging techniques. We have developed an automated method for attenuation correction that compensates for subject motion by deriving each set of correction factors from the corresponding emission study. Methods: The technique consists of generation of an estimated skull image by filtered backprojection of the reciprocal of an emission sinogram; estimation of the thickness and radius of the skull on profiles extracted from the image; scaling the radius and thickness values to generate a model of the brain, skull, and scalp; and assignment of attenuation coefficients to the head model for generation of attenuation correction factors. Values for scale factors and tissue attenuation coefficients were determined empirically by fitting the emission-derived head model to measured transmission data in five subjects using nonlinear regression (group A). The average model parameters, across five datasets (group A), were then used to generate attenuation maps for five independent emission studies (group B). Mean-squared-error values were calculated between the measured transmission data and the two model groups. For comparison, mean squared error values were calculated between the measured transmission data and homogeneous ellipses that were manually fitted to emission images. Results: The difference between the mean squared error for groups A and B was not significant (P > 0.8), indicating that model parameters from a small group can be used for other subjects without further fitting. The mean squared error for the automated method was significantly lower than that of the ellipse method (P < 0.001). The method reduced emission image variance, resulting in a higher peak Z value in activation images. The elimination of measured transmission scans resulted in a reduction in scan time (~15 min) and radiation exposure (~0.5–1.6 mrem). Conclusion: We have developed an automated attenuation correction method that compensates for subject motion between scans, accurately reproduces the characteristics of the head, and eliminates the use of measured transmission data to reduce scan duration, statistical noise propagation, and radiation dose.

Key Words: PET • attenuation correction • brain mapping • image processing, computer-assisted • CT, emission




This article has been cited by other articles:


Home page
JNMHome page
H. Zaidi and B. Hasegawa
Determination of the Attenuation Map in Emission Tomography
J. Nucl. Med., February 1, 2003; 44(2): 291 - 315.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.