JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Phillips, W. T.
Right arrow Articles by Goins, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Phillips, W. T.
Right arrow Articles by Goins, B.
Journal of Nuclear Medicine Vol. 42 No. 3 446-451
© 2001 by Society of Nuclear Medicine


BASIC SCIENCE INVESTIGATIONS

Use of 99mTc-Labeled Liposomes Encapsulating Blue Dye for Identification of the Sentinel Lymph Node

William T. Phillips, Robert Klipper and Beth Goins

Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas

Colloidal radiopharmaceuticals are commonly used in combination with blue dye for localization of the sentinel node. Liposomes are colloidal particles composed of spontaneously forming lipid spheres that can carry a wide variety of diagnostic and therapeutic agents. Conventional liposomes are poorly retained in lymph nodes (<2% of the subcutaneously injected dose). We have previously described a system for increasing the retention of liposomes in the lymph nodes by ~7-fold. This system is comprised of subcutaneously injected biotin-coated liposomes, followed by an adjacent injection of avidin. When the avidin moves into the lymphatic vessels, it causes aggregation of the biotin-coated liposomes that are also in the process of migrating through the lymphatic vessels. These aggregated liposomes become entrapped in the next encountered lymph node. In this study, we use this novel lymph node delivery system with liposomes that encapsulate blue dye, resulting in intense blue staining of the sentinel node. These liposomes can also be labeled with 99mTc, permitting scintigraphic imaging and radioguided probe localization of the sentinel node. Methods: Liposomes coated with biotin and coencapsulating blue dye and glutathione were labeled with 99mTc using hexamethylpropyleneamine oxime. Rabbits were subcutaneously administered 0.3 mL 99mTc-biotin-liposomes containing blue dye in both hind feet, followed by a subcutaneous injection (0.3 mL) of 5 mg avidin in only one hind foot (experimental). The other hind foot served as a control. Results: Labeling efficiencies (mean ± SEM) for liposomes encapsulating blue dye were 92.1% ± 1.9%. Necropsy at 24 h revealed that the popliteal node on the experimental leg receiving the avidin was intensely blue stained compared with virtually no blue coloration of the control node. Tissue counts of these nodes were 12.2 ± 1.5 percentage injected dose (%ID) in the experimental node compared with 1.2 ± 0.1 %ID in the control nodes (P < 0.0001). Conclusion: Biotin-liposomes encapsulating blue dye can be successfully labeled with 99mTc, providing a convenient option for the visualization and radiolocalization of the sentinel node. This biotin-liposome/avidin system may also have potential for the delivery of therapeutic drugs and radiopharmaceuticals to lymph nodes.

Key Words: liposomes • sentinel node • 99mTc • blue dye • avidin


Related articles in JNM:

Let Every Node Count!
Roger F. Uren
JNM 2001 42: 452-453. [Full Text]  



This article has been cited by other articles:


Home page
J. Pharmacol. Exp. Ther.Home page
W. T. Phillips, L. A. Medina, R. Klipper, and B. Goins
A Novel Approach for the Increased Delivery of Pharmaceutical Agents to Peritoneum and Associated Lymph Nodes
J. Pharmacol. Exp. Ther., October 1, 2002; 303(1): 11 - 16.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Tsopelas and R. Sutton
Why Certain Dyes Are Useful for Localizing the Sentinel Lymph Node
J. Nucl. Med., October 1, 2002; 43(10): 1377 - 1382.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. F. Uren
Let Every Node Count!
J. Nucl. Med., March 1, 2001; 42(3): 452 - 453.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.