BASIC SCIENCE INVESTIGATIONS |
Center for Functional Imaging, E.O. Lawrence Berkeley National Laboratory, University of California, Berkeley; Martinez Veterans Affairs, Northern California Health Care System, Martinez, California
The goal of this investigation was to assess the accuracy of 7'-Z-[125I]iodorotenone (125I-iodorotenone) as a new deposited myocardial flow tracer and compare the results with those for 99mTc-sestamibi. Methods: The kinetics of these two flow tracers were evaluated in 25 isolated, erythrocyte- and albumin-perfused rabbit hearts over a flow range relevant to patients. The two flow tracers and a vascular reference tracer (131I-albumin) were introduced simultaneously as a compact bolus through a port just above the aortic cannula in the absence of tracer recirculation. Myocardial extraction, retention, washout, and uptake parameters were computed from the venous outflow curves using the multiple-indicator dilution technique and spectral analysis. Results: The extraction of 125I-iodorotenone was much higher than the extraction of 99mTc-sestamibi (0.84 ± 0.05 vs. 0.48 ± 0.10, respectively, P < 0.001). 125I-iodorotenone extraction was also less affected by flow than was 99mTc-sestamibi (P < 0.001). Net retention of 125I-iodorotenone was significantly greater than 99mTc-sestamibi net retention at 1 min (0.77 ± 0.08 vs. 0.41 ± 0.11, respectively, P < 0.001) and 26 min (0.46 ± 0.13 vs. 0.27 ± 0.11, respectively, P < 0.001) after tracer injection. Flow had less effect on 125I-iodorotenone net retention than on 99mTc-sestamibi net retention 1 min after tracer injection (P < 0.04). However, at 26 min, flow had an equivalent effect on the retention of both flow tracers (P < 0.4). The relationship between 125I-iodorotenone and 99mTc-sestamibi washout was complex and depended on elapsed time after isotope introduction and perfusion rate. Reflecting the favorable extraction and retention characteristics of 125I-iodorotenone, both its maximum myocardial uptake and its 26-min uptake were more closely related to flow than were those of 99mTc-sestamibi (P < 0.001 for both comparisons). Conclusion: The extraction and retention of 125I-iodorotenone were greater than those of 99mTc-sestamibi, making 125I-iodorotenone the superior flow tracer in the isolated rabbit heart.
Key Words: PET SPECT myocardial perfusion
This article has been cited by other articles:
![]() |
R. C. Marshall, P. Powers-Risius, B. W. Reutter, J. P. O'Neil, M. La Belle, R. H. Huesman, and H. F. VanBrocklin Kinetic Analysis of 18F-Fluorodihydrorotenone as a Deposited Myocardial Flow Tracer: Comparison to 201Tl J. Nucl. Med., November 1, 2004; 45(11): 1950 - 1959. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. C. Marshall, P. Powers-Risius, B. W. Reutter, A. M. Schustz, C. Kuo, M. K. Huesman, and R. H. Huesman Flow heterogeneity following global no-flow ischemia in isolated rabbit heart Am J Physiol Heart Circ Physiol, February 1, 2003; 284(2): H654 - H667. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Llaurado The Quest for the Perfect Myocardial Perfusion Indicator...Still a Long Way to Go J. Nucl. Med., February 1, 2001; 42(2): 282 - 284. [Full Text] |
||||