JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lin, J.-W.
Right arrow Articles by Bergmann, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lin, J.-W.
Right arrow Articles by Bergmann, S. R.
Journal of Nuclear Medicine Vol. 42 No. 2 201-208
© 2001 by Society of Nuclear Medicine


CLINICAL INVESTIGATIONS

Quantification of Myocardial Perfusion in Human Subjects Using 82Rb and Wavelet-Based Noise Reduction

Jou-Wei Lin, Robert R. Sciacca, Ru-Ling Chou, Andrew F. Laine and Steven R. Bergmann

Division of Cardiology, Department of Medicine, and Department of Radiology, College of Physicians and Surgeons, Columbia University, New York; and Department of Biomedical Engineering, Columbia University, New York, New York

Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of flow estimates after the application of a novel multidimensional wavelet-based noise-reduction protocol. Methods: Myocardial perfusion was estimated using 82Rb and a two-compartment model from dynamic PET scans on 11 healthy volunteers at rest and after hyperemic stress with dipyridamole. Midventricular planes were divided into eight regions of interest, and a wavelet transform protocol was applied to images and time–activity curves. Flow estimates without and with the wavelet approach were compared with those obtained using H215O. Results: Over a wide flow range (0.45–2.75 mL/g/min), flow achieved with the wavelet approach correlated extremely closely with values obtained with H215O (y = 1.03 x -0.12; n = 23 studies, r = 0.94, P < 0.001). If the wavelet noise-reduction technique was not used, the correlation was less strong (y = 1.11 x + 0.24; n = 23 studies, r = 0.79, P < 0.001). In addition, the wavelet approach reduced the regional variation from 75% to 12% and from 62% to 11% (P < 0.001 for each comparison) for resting and stress studies, respectively. Conclusion: The use of a wavelet protocol allows near-optimal noise reduction, markedly enhances the physiologic flow signal within the PET images, and enables accurate measurement of myocardial perfusion with 82Rb in human subjects over a wide range of flows.

Key Words: PET • rubidium • myocardial perfusion • wavelets




This article has been cited by other articles:


Home page
JNMHome page
G. El Fakhri, A. Kardan, A. Sitek, S. Dorbala, N. Abi-Hatem, Y. Lahoud, A. Fischman, M. Coughlan, T. Yasuda, and M. F. Di Carli
Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET
J. Nucl. Med., July 1, 2009; 50(7): 1062 - 1071.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
G. El Fakhri, A. Sitek, B. Guerin, M. F. Kijewski, M. F. Di Carli, and S. C. Moore
Quantitative Dynamic Cardiac 82Rb PET Using Generalized Factor and Compartment Analyses
J. Nucl. Med., August 1, 2005; 46(8): 1264 - 1271.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Knesaurek, J. Machac, B. R. Krynyckyi, and O. D. Almeida
Comparison of 2-Dimensional and 3-Dimensional 82Rb Myocardial Perfusion PET Imaging
J. Nucl. Med., August 1, 2003; 44(8): 1350 - 1356.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J.-W. Lin, A. F. Laine, O. Akinboboye, and S. R. Bergmann
Use of Wavelet Transforms in Analysis of Time-Activity Data from Cardiac PET
J. Nucl. Med., February 1, 2001; 42(2): 194 - 200.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.