CLINICAL INVESTIGATIONS |
Division of Cardiology, Department of Medicine, and Department of Radiology, College of Physicians and Surgeons, Columbia University, New York; and Department of Biomedical Engineering, Columbia University, New York, New York
Quantification of myocardial perfusion with 82Rb has been difficult to achieve because of the low signal-to-noise ratio of the dynamic data curves. This study evaluated the accuracy of flow estimates after the application of a novel multidimensional wavelet-based noise-reduction protocol. Methods: Myocardial perfusion was estimated using 82Rb and a two-compartment model from dynamic PET scans on 11 healthy volunteers at rest and after hyperemic stress with dipyridamole. Midventricular planes were divided into eight regions of interest, and a wavelet transform protocol was applied to images and timeactivity curves. Flow estimates without and with the wavelet approach were compared with those obtained using H215O. Results: Over a wide flow range (0.452.75 mL/g/min), flow achieved with the wavelet approach correlated extremely closely with values obtained with H215O (y = 1.03 x -0.12; n = 23 studies, r = 0.94, P < 0.001). If the wavelet noise-reduction technique was not used, the correlation was less strong (y = 1.11 x + 0.24; n = 23 studies, r = 0.79, P < 0.001). In addition, the wavelet approach reduced the regional variation from 75% to 12% and from 62% to 11% (P < 0.001 for each comparison) for resting and stress studies, respectively. Conclusion: The use of a wavelet protocol allows near-optimal noise reduction, markedly enhances the physiologic flow signal within the PET images, and enables accurate measurement of myocardial perfusion with 82Rb in human subjects over a wide range of flows.
Key Words: PET rubidium myocardial perfusion wavelets
This article has been cited by other articles:
![]() |
G. El Fakhri, A. Kardan, A. Sitek, S. Dorbala, N. Abi-Hatem, Y. Lahoud, A. Fischman, M. Coughlan, T. Yasuda, and M. F. Di Carli Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with 82Rb PET: Comparison with 13N-Ammonia PET J. Nucl. Med., July 1, 2009; 50(7): 1062 - 1071. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. El Fakhri, A. Sitek, B. Guerin, M. F. Kijewski, M. F. Di Carli, and S. C. Moore Quantitative Dynamic Cardiac 82Rb PET Using Generalized Factor and Compartment Analyses J. Nucl. Med., August 1, 2005; 46(8): 1264 - 1271. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Knesaurek, J. Machac, B. R. Krynyckyi, and O. D. Almeida Comparison of 2-Dimensional and 3-Dimensional 82Rb Myocardial Perfusion PET Imaging J. Nucl. Med., August 1, 2003; 44(8): 1350 - 1356. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-W. Lin, A. F. Laine, O. Akinboboye, and S. R. Bergmann Use of Wavelet Transforms in Analysis of Time-Activity Data from Cardiac PET J. Nucl. Med., February 1, 2001; 42(2): 194 - 200. [Abstract] [Full Text] |
||||