JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Groch, M. W.
Right arrow Articles by Marshall, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Groch, M. W.
Right arrow Articles by Marshall, R. C.
Journal of Nuclear Medicine Vol. 42 No. 12 1773-1779
© 2001 by Society of Nuclear Medicine


Clinical Investigations

Planar Imaging Versus Gated Blood-Pool SPECT for the Assessment of Ventricular Performance: A Multicenter Study

Mark W. Groch, E. Gordon DePuey, Allan C. Belzberg, William D. Erwin, Mohammad Kamran, Charles A. Barnett, Robert C. Hendel, Stewart M. Spies, Amjad Ali and Robert C. Marshall

Northwestern University Medical School, Chicago; Rush-Presbyterian-St. Luke’s Medical Center, Chicago; Rush University, Chicago, Illinois; St. Luke’s-Roosevelt Hospital, New York; Columbia University, New York, New York; St. Paul’s Hospital, Vancouver, British Columbia; University of British Columbia, Vancouver, British Columbia, Canada; VA Medical Center, Martinez; University of California-Davis, Davis; and Lawrence Berkeley National Laboratory, Berkeley, California

Gated blood-pool SPECT (GBPS), inherently 3-dimensional (3D), has the potential to replace planar equilibrium radionuclide angiography (ERNA) for computation of left ventricular ejection fraction (LVEF), analysis of regional wall motion (RWM), and analysis of right heart function. The purpose of this study was to compare GBPS and ERNA for the assessment of ventricular function in a large, multicenter cohort of patients. Methods: One hundred seventy-eight patients referred in the usual manner for nuclear medicine studies underwent ERNA followed by GBPS. Each clinical site followed a GBPS acquisition protocol that included 180° rotation, a 64 by 64 matrix, and 64 or 32 views using single- or double-head cameras. Transverse GBPS images were reconstructed with a Butterworth filter (cutoff frequency, 0.45–0.55 Nyquist; order, 7), and short-axis images were created. All GBPS studies were processed with a new GBPS program, and LVEF was computed from the isolated left ventricular chamber and compared with standard ERNA LVEF. Reproducibility of GBPS LVEF was evaluated, and right ventricular ejection fraction (RVEF) was computed in a subset of patients (n = 33). Using GBPS, RWM and image quality from 3D surface-shaded and volume-rendered cine displays were evaluated qualitatively in a subset of patients (n = 30). Results: The correlation between GBPS LVEF and planar LVEF was excellent (r = 0.92). Mean LVEF was 62.2% for GBPS and 54.1% for ERNA. The line of linear regression was GBPS LVEF = (1.04 x ERNA LVEF) + 6.1. Bland–Altman plotting revealed an increasing bias in GBPS LVEF with increasing LVEF (Y = 0.13x + 0.61; r = 0.30; mean difference = 8.1% ± 7.0%). Interoperator reproducibility of GBPS LVEF was good (r = 0.92). RVEF values averaged 59.8%. RWM assessment using 3D cine display was enhanced in 27% of the studies, equivalent in 67%, and inferior in 7%. Conclusion: GBPS LVEF was reproducible and correlated well with planar ERNA. GBPS LVEF values were somewhat higher than planar ERNA, likely because of the exclusion of the left atrium.

Key Words: gated blood-pool imaging • gated SPECT • left ventricular ejection fraction




This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
X. Iriart, M. Montaudon, S. Lafitte, J. Chabaneix, P. Reant, T. Balbach, H. Houle, F. Laurent, and J.-B. Thambo
Right ventricle three-dimensional echography in corrected tetralogy of fallot: accuracy and variability
Eur J Echocardiogr, June 10, 2009; (2009) jep071v2.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
D. Mariano-Goulart, M.-C. Eberle, V. Boudousq, A. Hejazi-Moughari, C. Piot, C. C. de Kerleau, R. Verdier, M.-L. Barge, F. Comte, N. Bressot, et al.
Major increase in brain natriuretic peptide indicates right ventricular systolic dysfunction in patients with heart failure
Eur J Heart Fail, August 1, 2003; 5(4): 481 - 488.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.