JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sjögreen, K.
Right arrow Articles by Strand, S.-E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sjögreen, K.
Right arrow Articles by Strand, S.-E.
Journal of Nuclear Medicine Vol. 42 No. 10 1563-1570
© 2001 by Society of Nuclear Medicine


Basic Science Investigations

Registration of Emission and Transmission Whole-Body Scintillation-Camera Images

Katarina Sjögreen, Michael Ljungberg, Karin Wingårdh, Kjell Erlandsson and Sven-Erik Strand

Department of Radiation Physics, Jubileum Institute, University Hospital, Lund University, Lund, Sweden; and Institute of Nuclear Medicine, Middlesex Hospital, London, United Kingdom

In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. Methods: Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an 131I-labeled monoclonal antibody and for Monte Carlo–simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. Results: For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 105 (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 ± 5 mm. Conclusion: An automatic registration method for WB images has been developed, which is applicable to emission–emission and transmission–emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.

Key Words: whole-body image registration • conjugate view • planar activity quantification • mutual information




This article has been cited by other articles:


Home page
JNMHome page
K. S. Gleisner, M. Nickel, O. Linden, K. Erlandsson, K. Wingardh, and S.-E. Strand
Parametric Images of Antibody Pharmacokinetics Based on Serial Quantitative Whole-Body Imaging and Blood Sampling
J. Nucl. Med., August 1, 2007; 48(8): 1369 - 1378.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
L. Jonsson, M. Ljungberg, and S.-E. Strand
Evaluation of Accuracy in Activity Calculations for the Conjugate View Method from Monte Carlo Simulated Scintillation Camera Images Using Experimental Data in an Anthropomorphic Phantom
J. Nucl. Med., October 1, 2005; 46(10): 1679 - 1686.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Sjogreen, M. Ljungberg, and S.-E. Strand
An Activity Quantification Method Based on Registration of CT and Whole-Body Scintillation Camera Images, with Application to 131I
J. Nucl. Med., July 1, 2002; 43(7): 972 - 982.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.