Continuing Education |
Cedars-Sinai Medical Center, Los Angeles; and UCLA School of Medicine, Los Angeles, California
Myocardial perfusion SPECT imaging accounts for well over 90% of all myocardial perfusion imaging performed in the United States today. Although clearly superior to the traditional planar technique in terms of image contrast and consequent diagnostic and prognostic yield, the SPECT approach also involves additional acquisition and processing steps. This article concisely describes the entire technical sequence of myocardial SPECT imaging, from the acquisition of projection images to their filtration and tomographic reconstruction and concluding with reorientation of the tomographic transaxial images. A simplified explanation of the frequency, or Fourier, domain and the operation of digital filters is also presented to help the reader intuitively understand these important concepts.
Key Words: SPECT tomography principles myocardial
This article has been cited by other articles:
![]() |
D. Basso, G. Passmore, M. Holman, W. Rogers, L. Walters, T. Zecchin, and J. Butler Semiqualitative Visual and Quantitative Morphometric Evaluations of Reduced Scan Time and Wide-Beam Reconstruction in Rest-Gated Stress SPECT Myocardial Perfusion Imaging J. Nucl. Med. Technol., December 1, 2009; 37(4): 233 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Burrell and A. MacDonald Artifacts and Pitfalls in Myocardial Perfusion Imaging J. Nucl. Med. Technol., December 1, 2006; 34(4): 193 - 211. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. R. Zakavi, A. Zonoozi, V. D. Kakhki, M. Hajizadeh, M. Momennezhad, and K. Ariana Image Reconstruction Using Filtered Backprojection and Iterative Method: Effect on Motion Artifacts in Myocardial Perfusion SPECT J. Nucl. Med. Technol., December 1, 2006; 34(4): 220 - 223. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Vakhtangandze, D O Hall, F V Zananiri, and M R Rees The effect of Butterworth and Metz reconstruction filters on volume and ejection fraction calculations with 99Tcm gated myocardial SPECT Br. J. Radiol., August 1, 2005; 78(932): 733 - 736. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Wheat and G. M. Currie Impact of Patient Motion on Myocardial Perfusion SPECT Diagnostic Integrity: Part 2 J. Nucl. Med. Technol., September 1, 2004; 32(3): 158 - 163. [Abstract] [Full Text] [PDF] |
||||
![]() |
C Anagnostopoulos, M Harbinson, A Kelion, K Kundley, C Y Loong, A Notghi, E Reyes, W Tindale, and S R Underwood Procedure guidelines for radionuclide myocardial perfusion imaging Heart, January 1, 2004; 90(90001): i1 - 10. [Full Text] [PDF] |
||||
![]() |
A.F.L Schinkel, J.J Bax, M.L Geleijnse, E Boersma, A Elhendy, J.R.T.C Roelandt, and D Poldermans Noninvasive evaluation of ischaemic heart disease: myocardial perfusion imaging or stress echocardiography? Eur. Heart J., May 1, 2003; 24(9): 789 - 800. [Full Text] [PDF] |
||||
![]() |
P. P. Bruyant Analytic and Iterative Reconstruction Algorithms in SPECT J. Nucl. Med., October 1, 2002; 43(10): 1343 - 1358. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |