JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lebtahi, R.
Right arrow Articles by Le Guludec, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lebtahi, R.
Right arrow Articles by Le Guludec, D.
Journal of Nuclear Medicine Vol. 42 No. 1 21-26
© 2001 by Society of Nuclear Medicine


CLINICAL INVESTIGATIONS

Somatostatin Receptor Scintigraphy and Gallium Scintigraphy in Patients with Sarcoidosis

Rachida Lebtahi, Bruno Crestani, Nadia Belmatoug, Doumit Daou, Remi Genin, Marie Christine Dombret, Elisabeth Palazzo, Marc Faraggi, Michel Aubier and Dominique Le Guludec

Departments of Nuclear Medicine, Pneumology, and Rheumatology, Hôpital Bichat, Assistance Publique Hôpitaux de Paris, Paris; and Department of Internal Medicine, Hôpital Beaujon, Assistance Publique Hôpitaux de Paris, Paris, France

Somatostatin receptor scintigraphy (SRS) has been shown to reveal sarcoidosis sites. The aim of this study was to prospectively compare SRS and gallium scintigraphy in the evaluation of pulmonary and extrapulmonary involvement in patients with proven sarcoidosis. Methods: Eighteen patients with biopsy-proven sarcoidosis were included. Nine were or recently had been receiving steroid therapy at the time of the examination. Planar gallium scintigraphy (head, chest, abdomen, and pelvis) and thoracic SPECT were performed at 48–72 h after injection of a mean dose of 138 ± 21 MBq 67Ga. Planar SRS and thoracic SPECT were performed at 4 and 24 h after injection of a mean dose of 148 ± 17 MBq 111In-pentetreotide. Results: Gallium scintigraphy found abnormalities in 16 of 18 patients (89%) and detected 64 of 99 clinically involved sites (65%). SRS found abnormalities in 18 of 18 patients and detected 82 of 99 clinically involved sites (83%). Of the 9 treated patients, gallium scintigraphy found abnormalities in 7 (78%), detecting 23 of 39 clinically involved sites (59%), whereas SRS found abnormalities in 9, detecting 32 of 39 clinically involved sites (82%). Conclusion: This study suggests that, compared with gallium scintigraphy, SRS appears to be accurate and contributes to a better evaluation of organ involvement in sarcoidosis patients, especially those treated with corticosteroids.

Key Words: somatostatin receptor scintigraphy • gallium scintigraphy • sarcoidosis




This article has been cited by other articles:


Home page
JNMHome page
Y. Nishiyama, Y. Yamamoto, K. Fukunaga, H. Takinami, Y. Iwado, K. Satoh, and M. Ohkawa
Comparative Evaluation of 18F-FDG PET and 67Ga Scintigraphy in Patients with Sarcoidosis
J. Nucl. Med., October 1, 2006; 47(10): 1571 - 1576.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. Lebtahi, S. Moreau, S. Marchand-Adam, M.-P. Debray, M. Brauner, P. Soler, J. Marchal, O. Raguin, A. Gruaz-Guyon, J.-C. Reubi, et al.
Increased Uptake of 111In-Octreotide in Idiopathic Pulmonary Fibrosis
J. Nucl. Med., August 1, 2006; 47(8): 1281 - 1287.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
A. F. Shorr, D. L. Helman, C. J. Lettieri, J. L. Montilla, and R. S. Bridwell
Depreotide Scanning in Sarcoidosis: A Pilot Study
Chest, October 1, 2004; 126(4): 1337 - 1343.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2001 by the Society of Nuclear Medicine.