JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 41 No. 9 1484-1490
© 2000 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wakita, K.
Right arrow Articles by Kanatsuna, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wakita, K.
Right arrow Articles by Kanatsuna, T.

Simplification for Measuring Input Function of FDG PET: Investigation of 1-Point Blood Sampling Method

Kazuo Wakita, Yoshio Imahori, Tatsuo Ido, Ryou Fujii, Hitoshi Horii, Misato Shimizu, Sachiko Nakajima, Katsuyoshi Mineura, Takakazu Nakamura and Takahiro Kanatsuna

Clinical PET Center, Nishijin Hospital, Kamigyo-ku, Kyoto
Department of Neurosurgery, Kyoto Prefectural University of Medicine, Kamigyo-ku, Kyoto
Cyclotron and Radioisotope Center, Tohoku University, Sendai, Japan

Correspondence: For correspondence or reprints contact: Yoshio Imahori, MD, PhD, Department of Neurosurgery, Kyoto Prefectural University of Medicine, Kawaramachi-Hirokoji, Kamlgyo-ku 602-0841, Kyoto, Japan.

ABSTRACT

The current method for quantitative FDG PET study requires application of multiple arterial blood sampling for measuring the input function, but the procedure is invasive and complicated. The purpose of this study was to establish a 1-point blood sampling technique that gives data comparable with the data of more elaborate serial arterial sampling. Methods: We established a time point for 1-point arterial sampling that exhibited the highest correlation between plasma radioactivity at the time point and the real integrated value (IV) of the measured input function obtained by multiple arterial sampling in 120 patients and the smallest coefficient of variation of the real IV divided by plasma radioactivity at the time point in 120 patients. Scaling factors for estimation at each sampling point were determined, and a reference table was established to make the supposed input function. Results: The optimal time for 1-point arterial sampling was 12 min after FDG injection. A good correlation was observed between the real IVs and those estimated from 1-point arterial blood sampling at 12 min using the supposed input function (n = 120; P < 0.001). The time point at which the difference between values of arterial and venous blood disappeared was 40 min after FDG injection. The percentage errors of IV estimation by 1-point sampling were 1.70% (n = 120) for arterial blood at 12 min and 3.64% (n = 10) for venous blood at 40 min. Conclusion: We conclude that the simplified 1-point sample method works in a manner that is comparable with serial arterial sampling and should be useful for clinical PET.

Key Words: PET • glucose metabolic rate • FDG • input function • blood sampling • clinical PET