The Journal of Nuclear Medicine Vol. 41 No. 4 737-744
© 2000 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lalush, D. S.
Right arrow Articles by Tsui, B. M.W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lalush, D. S.
Right arrow Articles by Tsui, B. M.W.

Performance of Ordered-Subset Reconstruction Algorithms Under Conditions of Extreme Attenuation and Truncation in Myocardial SPECT

David S. Lalush and Benjamin M.W. Tsui

Departments of Biomedical Engineering and Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina

Correspondence: For correspondence or reprints contact: David S. Lalush, PhD, Department of Biomedical Engineering, CB 7575, 152 MacNider Hall, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7575.

ABSTRACT

We studied the bias and variance characteristics of the ordered-subset expectation maximization (OSEM) and rescaled block-iterative EM (RBIEM) iterative reconstruction algorithms in myocardial SPECT under extreme, but realistic, conditions. Methods: We used the 2-dimensional mathematic cardiac torso phantom to simulate 2 patient anatomies: a large male with a raised diaphragm and a female with large breast size, approximating extreme cases of attenuation conditions found in the clinic. For each anatomy, realistic 201Tl projection data were simulated for a 180° acquisition arc. Three cases of truncation for a 90°-configured dual detector system were simulated: no truncation, moderate truncation, and extreme truncation. For each case, an ensemble of 250 noise simulations was generated, and each noisy dataset was reconstructed with the OSEM and RBIEM algorithms. The reconstructions modeled only the effects of nonuniform attenuation and used a range of subset configurations. Over the ensemble, we computed means and variances of activity in 8 regions of interest (ROIs) in the heart as a function of iteration. Results: Under conditions of no truncation and moderate truncation, the results from OSEM and RBIEM were very close to those from maximum-likelihood EM (MLEM); in all cases, the difference in ROI means was <2.5%. For extreme truncation, the errors increased to as much as 11% with OSEM, but these were no greater than the errors for MLEM under the same conditions. The OSEM algorithm with 2 views per subset was found to result in much higher variance of ROI estimates for the same bias as compared with RBIEM or OSEM with 4 or more views per subset. Conclusion: The OSEM and RBIEM algorithms are at least as robust to highly attenuating patients and truncation as MLEM algorithm and can be adequate substitutes for MLEM, even in extreme cases. Clinical users should apply the smallest number of subsets that can be accommodated by allowable processing time to reduce image noise and variance in quantitative estimates.

Key Words: iterative reconstruction • attenuation compensation • myocardial SPECT




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
L. K. Leong, R. L. Kruger, and M. K. O'Connor
A Comparison of the Uniformity Requirements for SPECT Image Reconstruction Using FBP and OSEM Techniques
J. Nucl. Med. Technol., June 1, 2001; 29(2): 79 - 83.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
M. W. Groch and W. D. Erwin
SPECT in the Year 2000: Basic Principles
J. Nucl. Med. Technol., December 1, 2000; 28(4): 233 - 244.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2000 by the Society of Nuclear Medicine.