JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 41 No. 12 2083-2088
© 2000 by Society of Nuclear Medicine
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Slifstein, M.
Right arrow Articles by Laruelle, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Slifstein, M.
Right arrow Articles by Laruelle, M.

Effects of Statistical Noise on Graphic Analysis of PET Neuroreceptor Studies

Mark Slifstein and Marc Laruelle

Departments of Psychiatry and Radiology, Columbia University College of Physicians and Surgeons, New York; and Division of Brain Imaging, Department of Neuroscience, New York State Psychiatric Institute, New York, New York

Because of its computational simplicity, the graphic method introduced by Logan et al. is frequently used to analyze time–activity curves of reversible radiotracers measured in brain regions with PET. The graphic method uses a nonlinear transformation of data to variables that have an asymptotically linear relationship. Compared with compartmental analysis of untransformed data, the graphic method enables derivation of regional distribution volumes that are free from assumptions about the underlying compartmental configuration. In this article, we describe statistical bias associated with this nonlinear transformation method. Methods: Theoretic analysis, Monte Carlo simulation, and statistical analysis of PET data were used to test the graphic method for bias. Results: Mean zero noise is associated with underestimation of distribution volumes when data are analyzed with graphic analysis, whereas this effect does not occur when the same data are analyzed by nonlinear regression and compartmental analysis. Moreover, this effect depends on the magnitude of the distribution volume, so that the bias is more pronounced in regions with high receptor density than regions with low receptor density or no receptors (region of reference). Conclusion: These results indicate that conventional kinetic analysis of untransformed data is less sensitive to mean zero noise than is graphic analysis of nonlinearly transformed data.

Key Words: PET • kinetic modeling • graphic analysis • noise

Received Dec. 13, 1999; revision accepted May 5, 2000.

For correspondence or reprints contact: Mark Slifstein, PhD, New York State Psychiatric Institute, 1051 Riverside Dr., Unit 31, New York, NY 10032.




This article has been cited by other articles:


Home page
JNMHome page
M. S. Milak, A. J. Severance, R. T. Ogden, J. Prabhakaran, J.S. D. Kumar, V. J. Majo, J. J. Mann, and R. V. Parsey
Modeling Considerations for 11C-CUMI-101, an Agonist Radiotracer for Imaging Serotonin 1A Receptor In Vivo with PET
J. Nucl. Med., April 1, 2008; 49(4): 587 - 596.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
V. G. Frokjaer, L. H. Pinborg, J. Madsen, R. de Nijs, C. Svarer, A. Wagner, and G. M. Knudsen
Evaluation of the Serotonin Transporter Ligand 123I-ADAM for SPECT Studies on Humans
J. Nucl. Med., February 1, 2008; 49(2): 247 - 254.
[Abstract] [Full Text] [PDF]


Home page
J PsychopharmacolHome page
R. Buchert, F. Thiele, R. Thomasius, F. Wilke, K. Petersen, W. Brenner, J. Mester, L. Spies, and M. Clausen
Ecstasy-induced reduction of the availability of the brain serotonin transporter as revealed by [11C](+)McN5652-PET and the multi-linear reference tissue model: loss of transporters or artifact of tracer kinetic modelling?
J Psychopharmacol, August 1, 2007; 21(6): 628 - 634.
[Abstract] [PDF]


Home page
Arch Gen PsychiatryHome page
M. A. Oquendo, R. S. Hastings, Y.-y. Huang, N. Simpson, R. T. Ogden, X.-z. Hu, D. Goldman, V. Arango, R. L. Van Heertum, J. J. Mann, et al.
Brain Serotonin Transporter Binding in Depressed Patients With Bipolar Disorder Using Positron Emission Tomography
Arch Gen Psychiatry, February 1, 2007; 64(2): 201 - 208.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
W. G. Frankle, M. Slifstein, R. N. Gunn, Y. Huang, D.-R. Hwang, E. A. Darr, R. Narendran, A. Abi-Dargham, and M. Laruelle
Estimation of Serotonin Transporter Parameters with 11C-DASB in Healthy Humans: Reproducibility and Comparison of Methods
J. Nucl. Med., May 1, 2006; 47(5): 815 - 826.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. T. Meyer, D. Elmenhorst, A. Matusch, O. Winz, K. Zilles, and A. Bauer
18F-CPFPX PET: On the Generation of Parametric Images and the Effect of Scan Duration
J. Nucl. Med., February 1, 2006; 47(2): 200 - 207.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Boecker, T. Sprenger, G. Henriksen, T. R. Toelle, and M. E. Spilker
Optimal Duration of PET Studies with 18F-Fluoroethyl-Diprenorphine
J. Nucl. Med., December 1, 2005; 46(12): 2092 - 2096.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
L. H. Pinborg, M. Ziebell, V. G. Frokjaer, R. de Nijs, C. Svarer, S. Haugbol, S. Yndgaard, and G. M. Knudsen
Quantification of 123I-PE2I Binding to Dopamine Transporter with SPECT After Bolus and Bolus/Infusion
J. Nucl. Med., July 1, 2005; 46(7): 1119 - 1127.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Herzog, L. Tellmann, R. Fulton, I. Stangier, E. R. Kops, K. Bente, C. Boy, R. Hurlemann, and U. Pietrzyk
Motion Artifact Reduction on Parametric PET Images of Neuroreceptor Binding
J. Nucl. Med., June 1, 2005; 46(6): 1059 - 1065.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J.-D. Gallezot, M. Bottlaender, M.-C. Gregoire, D. Roumenov, J.-R. Deverre, C. Coulon, M. Ottaviani, F. Dolle, A. Syrota, and H. Valette
In Vivo Imaging of Human Cerebral Nicotinic Acetylcholine Receptors with 2-18F-Fluoro-A-85380 and PET
J. Nucl. Med., February 1, 2005; 46(2): 240 - 247.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. K. Yoder, C. Wang, and E. D. Morris
Change in Binding Potential as a Quantitative Index of Neurotransmitter Release Is Highly Sensitive to Relative Timing and Kinetics of the Tracer and the Endogenous Ligand
J. Nucl. Med., May 1, 2004; 45(5): 903 - 911.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D.-R. Hwang, R. Narendran, Y. Huang, M. Slifstein, P. S. Talbot, Y. Sudo, B. N. Van Berckel, L. S. Kegeles, D. Martinez, and M. Laruelle
Quantitative Analysis of (-)-N-11C-Propyl-Norapomorphine In Vivo Binding in Nonhuman Primates
J. Nucl. Med., February 1, 2004; 45(2): 338 - 346.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2000 by the Society of Nuclear Medicine.