JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 41 No. 11 1784-1792
© 2000 by Society of Nuclear Medicine
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lodge, M. A.
Right arrow Articles by Bacharach, S. L.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Lodge, M. A.
Right arrow Articles by Bacharach, S. L.

Parametric Images of Blood Flow in Oncology PET Studies Using [15O]Water

Martin A. Lodge, Richard E. Carson, Jorge A. Carrasquillo, Millie Whatley, Steven K. Libutti and Stephen L. Bacharach

The Clinical Center and the National Cancer Institute, National Institutes of Health, Bethesda, Maryland

PET was used to measure tumor blood flow, which is potentially valuable for diagnosis and assessing the effects of therapy. To help visualize regional differences in blood flow and to improve the accuracy of region-of-interest placement, a parametric imaging approach was developed and compared with the standard region-of-interest method. Methods: Five patients with renal cell metastases in the thorax were studied using [15O]water and dynamic PET. To assess the reproducibility of the blood flow measurements, multiple water studies were performed on each patient. Model fitting was done on a pixel-by-pixel basis using several different formulations of the standard single-compartment model. Results: The tumors studied spanned a wide range of blood flows, varying from 0.4 to 4.2 mL/min/g. These values were generally high compared with those of most other tissues, which meant that the tumors could be readily identified in parametric images of flow. The different model formulations produced images with different characteristics, and no model was entirely valid throughout the field of view. Although tumor blood flow measured from the parametric images was largely unbiased with respect to a standard regional method, large errors were observed with certain models in regions of low flow. The most robust model throughout the field of view had only 1 free parameter and, compared with a regional method, gave rise to a flow bias of 0.3% ± 3.1% for tumor and 16% ± 11% for low-flow soft tissue (muscle plus fat). With this model, tumor blood flow was measured with an SD of 7.6% ± 4.0%. Conclusion: Parametric imaging provides a convenient way of visualizing regional changes in blood flow, which may be valuable in studies of tumor blood flow.

Key Words: PET • [15O]water • parametric image • tumor blood flow

Received Oct. 29, 1999; revision accepted May 5, 2000.

For correspondence or reprints contact: Stephen L. Bacharach, PhD, Rm. 1C401, Bldg. 10, National Institutes of Health, Bethesda, MD 20892-1180.




This article has been cited by other articles:


Home page
JNMHome page
M. A. Lodge, H. A. Jacene, R. Pili, and R. L. Wahl
Reproducibility of Tumor Blood Flow Quantification with 15O-Water PET
J. Nucl. Med., October 1, 2008; 49(10): 1620 - 1627.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. Bao, B. Goins, G. D. Dodd III, A. Soundararajan, C. Santoyo, R. A. Otto, M. D. Davis, and W. T. Phillips
Real-Time Iterative Monitoring of Radiofrequency Ablation Tumor Therapy with 15O-Water PET Imaging
J. Nucl. Med., October 1, 2008; 49(10): 1723 - 1729.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
A. J. de Langen, V. E. M. van den Boogaart, J. T. Marcus, and M. Lubberink
Use of H215O-PET and DCE-MRI to Measure Tumor Blood Flow
Oncologist, June 1, 2008; 13(6): 631 - 644.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. Soret, S. L. Bacharach, and I. Buvat
Partial-Volume Effect in PET Tumor Imaging
J. Nucl. Med., June 1, 2007; 48(6): 932 - 945.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. Knaapen, R. Boellaard, M. J.W. Gotte, P. A. Dijkmans, L. M.C. van Campen, C. C. de Cock, G. Luurtsema, C. A. Visser, A. A. Lammertsma, and F. C. Visser
Perfusable Tissue Index as a Potential Marker of Fibrosis in Patients with Idiopathic Dilated Cardiomyopathy
J. Nucl. Med., August 1, 2004; 45(8): 1299 - 1304.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
C. J. Hoekstra, S. G. Stroobants, O. S. Hoekstra, E. F. Smit, J. F. Vansteenkiste, and A. A. Lammertsma
Measurement of Perfusion in Stage IIIA-N2 Non-Small Cell Lung Cancer Using H215O and Positron Emission Tomography
Clin. Cancer Res., July 1, 2002; 8(7): 2109 - 2115.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2000 by the Society of Nuclear Medicine.