JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 41 No. 1 123-130
© 2000 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dewaraja, Y. K.
Right arrow Articles by Koral, K. F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dewaraja, Y. K.
Right arrow Articles by Koral, K. F.

Characterization of Scatter and Penetration Using Monte Carlo Simulation in 131I Imaging

Yuni K. Dewaraja, Michael Ljungberg and Kenneth F. Koral

Internal Medicine Department, Division of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Michigan
Department of Radiation Physics, University of Lund, Lund, Sweden

Correspondence: For correspondence or reprints contact: Yuni K. Dewaraja, PhD, 3480 Kresge III, University of Michigan Medical Center, 204 Zina Pitcher PI., Ann Arbor, MI 48109-0552.

ABSTRACT

In 131I SPECT, image quality and quantification accuracy are degraded by object scatter as well as scatter and penetration in the collimator. The characterization of energy and spatial distributions of scatter and penetration performed in this study by Monte Carlo simulation will be useful for the development and evaluation of techniques that compensate for such events in 131I imaging. Methods: First, to test the accuracy of the Monte Carlo model, simulated and measured data were compared for both a point source and a phantom. Next, simulations to investigate scatter and penetration were performed for four geometries: point source in air, point source in a water-filled cylinder, hot sphere in a cylinder filled with nonradioactive water, and hot sphere in a cylinder filled with radioactive water. Energy spectra were separated according to order of scatter, type of interaction, and {gamma}-ray emission energy. A preliminary evaluation of the triple-energy window (TEW) scatter correction method was performed. Results: The accuracy of the Monte Carlo model was verified by the good agreement between measured and simulated energy spectra and radial point spread functions. For a point source in air, simulations show that 73% of events in the photopeak window had either scattered in or penetrated the collimator, indicating the significance of collimator interactions. For a point source in a water-filled phantom, the separated energy spectra showed that a 20% photopeak window can be used to eliminate events that scatter more than two times in the phantom. For the hot sphere phantoms, it was shown that in the photopeak region the spectrum shape of penetration events is very similar to that of primary (no scatter and no penetration) events. For the hot sphere regions of interest, the percentage difference between true scatter counts and the TEW estimate of scatter counts was <12%. Conclusion: In 131I SPECT, object scatter as well as collimator scatter and penetration are significant. The TEW method provides a reasonable correction for scatter, but the similarity between the 364-keV primary and penetration energy spectra makes it difficult to compensate for these penetration events using techniques that are based on spectral analysis.

Key Words: scatter correction • penetration • 131I imaging • SPECT • Monte Carlo simulated data




This article has been cited by other articles:


Home page
JNMHome page
M. Ljungberg, K. Sjogreen, X. Liu, E. Frey, Y. Dewaraja, and S.-E. Strand
A 3-Dimensional Absorbed Dose Calculation Method Based on Quantitative SPECT for Radionuclide Therapy: Evaluation for 131I Using Monte Carlo Simulation
J. Nucl. Med., August 1, 2002; 43(8): 1101 - 1109.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Sjogreen, M. Ljungberg, and S.-E. Strand
An Activity Quantification Method Based on Registration of CT and Whole-Body Scintillation Camera Images, with Application to 131I
J. Nucl. Med., July 1, 2002; 43(7): 972 - 982.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
Y. K. Dewaraja, M. Ljungberg, and K. F. Koral
Accuracy of 131I Tumor Quantification in Radioimmunotherapy Using SPECT Imaging with an Ultra-High-Energy Collimator: Monte Carlo Study
J. Nucl. Med., October 1, 2000; 41(10): 1760 - 1767.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 2000 by the Society of Nuclear Medicine.