Departments of Diagnostic Radiology and Nuclear Medicine and Electrical and Computer Engineering, University of Western Ontario, London, Ontario, Canada
Correspondence: For correspondence or reprints contact: Piotr Slomka, PhD, Nuclear Medicine Department, London Health Sciences Center, 375 South St., London, Ontario N5A4G5, Canada.
ABSTRACT
In nuclear medicine practice, images often need to be reviewed and reports prepared from locations outside the department, usually in the form of hard copy. Although hard-copy images are simple and portable, they do not offer electronic data search and image manipulation capabilities. On the other hand, picture archiving and communication systems or dedicated workstations cannot be easily deployed at numerous locations. To solve this problem, we propose a Java-based remote viewing station (JaRViS) for the reading and reporting of nuclear medicine images using Internet browser technology. Methods: JaRViS interfaces to the clinical patient database of a nuclear medicine workstation. All JaRViS software resides on a nuclear medicine department server. The contents of the clinical database can be searched by a browser interface after providing a password. Compressed images with the Java applet and color lookup tables are downloaded on the client side. This paradigm does not require nuclear medicine software to reside on remote computers, which simplifies support and deployment of such a system. To enable versatile reporting of the images, color tables and thresholds can be interactively manipulated and images can be displayed in a variety of layouts. Image filtering, frame grouping (adding frames), and movie display are available. Tomographic mode displays are supported, including gated SPECT. Results: The time to display 14 lung pertusion images in 128 x 128 matrix together with the Java applet and color lookup tables over a V.90 modem is <1 min. SPECT and PET slice reorientation is interactive (<1 s). JaRViS could run on a Windows 95/98/NT or a Macintosh platform with Netscape Communicator or Microsoft Internet Explorer. The performance of Java code for bilinear interpolation, cine display, and filtering approaches that of a standard imaging workstation. Conclusion: It is feasible to set up a remote nuclear medicine viewing station using Java and an Internet or intranet browser. Images can be made easily and cost-effectively available to referring physicians and ambulatory clinics within and outside of the hospital, providing a convenient alternative to film media. We also find this system useful in home reporting of emergency procedures such as lung ventilation-perfusion scans or dynamic studies.
Key Words: telemedicine picture archiving and communication systems Java
This article has been cited by other articles:
![]() |
S. Pauwels, R. Barone, S. Walrand, F. Borson-Chazot, R. Valkema, L. K. Kvols, E. P. Krenning, and F. Jamar Practical Dosimetry of Peptide Receptor Radionuclide Therapy with 90Y-Labeled Somatostatin Analogs J. Nucl. Med., January 1, 2005; 46(1_suppl): 92S - 98S. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Barone, F. Borson-Chazot, R. Valkema, S. Walrand, F. Chauvin, L. Gogou, L. K. Kvols, E. P. Krenning, F. Jamar, and S. Pauwels Patient-Specific Dosimetry in Predicting Renal Toxicity with 90Y-DOTATOC: Relevance of Kidney Volume and Dose Rate in Finding a Dose-Effect Relationship J. Nucl. Med., January 1, 2005; 46(1_suppl): 99S - 106S. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Ratib PET/CT Image Navigation and Communication J. Nucl. Med., January 1, 2004; 45(90010): 46S - 55. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Knoll, S. Mirzaei, K. Koriska, and H. Köhn Advanced Medical Imaging Project J. Nucl. Med., February 1, 2001; 42(2): 390 - 391. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |