JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 40 No. 7 1122-1124
© 1999 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Russell, C. D.
Right arrow Articles by Dubovsky, E. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Russell, C. D.
Right arrow Articles by Dubovsky, E. V.

Reproducibility of Single-Sample Clearance of 99mTc-Mercaptoacetyltriglycine and 131I-Orthoiodohippurate

Charles D. Russell and Eva V. Dubovsky

Division of Nuclear Medicine, University of Alabama Medical Center, and Veterans Administration Medical Center, Birmingham, Alabama

Correspondence: For correspondence or reprints contact: Charles D. Russell, MD, PhD, Division of Nuclear Medicine, University of Alabama Hospitals, 619 S. 19th St., Birmingham, AL 35233.

ABSTRACT

Recent literature has questioned whether 99mTc-mercaptoacetyltriglycine (MAG3) clearance measurements are reproducible enough for routine clinical monitoring of renal function. For many years, we have routinely followed the renal function of patients with spinal cord injuries using a combination of radionuclide imaging and clearance measurement. Methods: In this study, we retrospectively review 1626 effective renal plasma flow (ERPF) measurements in 197 patients with paraplegia or quadriplegia performed over a 21-y period, using 131I-orthoiodohippurate (OIH) through 1990 and MAG3 since 1991. MAG3 clearance was divided by 0.53 to convert it to ERPF. Reproducibility was measured as pooled SD from the single-patient linear regression lines of ERPF versus time. Results and Conclusion: There was no significant difference between MAG3 (SD = 46 ml/min, n = 907) and OIH (SD = 52 mL/min, n = 719). The data were therefore combined to obtain the SD for a single ERPF measurement, which was 49 mL/min. The corresponding coefficient of variation was 8.5% of the mean value of 581 mL/min. In our experience, this is adequate for monitoring the renal function of these patients.

Key Words: renal clearance • precision • mercaptoacetyltriglycine • orthoiodohippurate • kidney function