JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 40 No. 6 1011-1023
© 1999 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Vries, D. J.
Right arrow Articles by Metz, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Vries, D. J.
Right arrow Articles by Metz, C. E.

Effects of Scatter Subtraction on Detection and Quantitation in Hepatic SPECT

Daniel J. de Vries, Michael A. King, Edward J. Soares, Benjamin M.W. Tsui and Charles E. Metz

Department of Nuclear Medicine, University of Massachusetts Medical School, Worcester
Department of Mathematics, College of the Holy Cross, Worcester, Massachusetts
Department of Biomedical Engineering and Department of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
Department of Radiology, University of Chicago Medical Center, Chicago, Illinois

Correspondence: For correspondence or reprints contact: Daniel J. de Vries, PhD, Department of Radiology, Brigham & Women's Hospital, 75 Francis St., Boston, MA 02115.

ABSTRACT

The purpose of this investigation was to examine the effects of subtractive scatter compensation methods on lesion detection and quantitation. Methods: Receiver operating characteristic (ROC) methodology was used to measure human observer detection accuracy for tumors in the liver using synthetic images. Furthermore, ROC results were compared with mathematical models for detection and activity quantitation to examine (a) the potential for predicting human performance and (b) the relationship between the detection and quantitation tasks. Images with both low and high amounts of scatter were compared with the ideal case of images of primary photons only (i.e., perfect scatter rejection) and with images corrected by subtracting a scatter image estimated by the dual photopeak window method. Results: With low contrast tumors in a low count background, the results showed that scatter subtraction improved quantitation but did not produce statistically significant increases in detection accuracy. However, primary images did produce some statistically significant improvements in detection accuracy when compared with uncorrected images, particularly for high levels of scatter. Conclusion: Although scatter subtraction methods may provide improved activity quantitation, they may not significantly improve detection for liver SPECT. The results imply that significant improvement in detection accuracy for the conditions tested may depend on the development of gamma cameras with better scatter rejection.

Key Words: lesion detection • receiver operating characteristic analysis • scatter correction




This article has been cited by other articles:


Home page
JNMHome page
T. H. Farncombe, H. C. Gifford, M. V. Narayanan, P. H. Pretorius, E. C. Frey, and M. A. King
Assessment of Scatter Compensation Strategies for 67Ga SPECT Using Numerical Observers and Human LROC Studies
J. Nucl. Med., May 1, 2004; 45(5): 802 - 812.
[Abstract] [Full Text] [PDF]