JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 40 No. 5 868-875
© 1999 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barthe, N.
Right arrow Articles by Charpak, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barthe, N.
Right arrow Articles by Charpak, G.

Optimization of a New Scintillation Gas Detector Used to Localize Electrons Emitted by 99mTc

Nicole Barthe, Philippe Coulon, Claude Hennion, Dominique Ducassou, Bernard Basse-Cathalinat and Georges Charpak

Laboratoire de Biophysique, Université Victor Segalen Bordeaux 2, Bordeaux
Ecole Supérieure de Physique et Chimie Industrielles, Paris, France

Correspondence: For correspondence or reprints contact: Nicole Barthe, Laboratoire de Biophysique, Université Victor Segalen Bordeaux 2, 146 rue Léo Saignat, 33076 Bordeaux, France.

ABSTRACT

We have developed a scintillation gas detector to localize electrons emitted by 99mTc. This type of detector allows direct quantification of images and so provides a clear advantage over autoradiographic film. We have optimized the device to give an image spatial resolution that closely approximates that of typical autoradiographic film. To improve this resolution, it was necessary to select only low-energy electrons (2 and 15 keV) and to devise novel detection and localization techniques for the ionizing particles. Methods: A parallel-plate proportional avalanche chamber is subject to a uniform electrical field and amplifies the number of released electrons through collisions of ionizing particles in the gas mixture. Light emitted by the gas scintillator during the avalanche process is collected by a highly intensified charge coupled device camera. The centroid of each resulting light distribution is calculated, resulting in a quantitative mapping of the sample's activity. Insertion of the sample within the gas volume improves the efficiency and so provides a method that is both very sensitive and linear. Results: We have shown that in a parallel-plate structure, the application of a high electrical field to the surface of the sample and the selection of appropriate light spots, according to their morphology, can overcome localization errors due to the particles' trajectories. We have obtained a resolution of the order of 30 µm, using electrons from 99mTc. Conclusion: This detection technique allows considerable improvement in image resolution. This "electron camera" is a serious rival to existing autoradiographic techniques, because it provides certain other advantages, including direct quantification, linearity, high dynamic range and low noise levels. Thus, new perspectives are made available in quantitative double tracer autoradiography, because electrons can be selected for imaging as a function of their energy.

Key Words: 99mTc • autoradiography • scintillation gas detector • avalanche chamber