JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 40 No. 12 2021-2024
© 1999 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bleckmann, C.
Right arrow Articles by Clausen, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bleckmann, C.
Right arrow Articles by Clausen, M.

Effect of Attenuation Correction on Lesion Detectability in FDG PET of Breast Cancer

Christian Bleckmann, Jörg Dose, Karl H. Bohuslavizki, Ralph Buchert, Susanne Klutmann, Janos Mester, Fritz Jänicke and Matte Clausen

Departments of Nuclear Medicine and Gynecology and Obstetrics, University Hospital Eppendorf, Hamburg, Germany

Correspondence: For correspondence or reprints contact: Karl H. Bohuslavizki, MD, PhD, Department of Nuclear Medicine, University Hospital Eppendorf, Martinistr. 52, D-20246 Hamburg, Germany.

ABSTRACT

The aim of this study was to compare the visual analysis of attenuation-corrected and noncorrected 18F-fluoro-2-deoxy-D-glucose (FDG) PET images in patients with primary or metastatic breast cancer using standardized film documentation and to evaluate the influence of attenuation correction on lesion detect ability. Methods: Standard FDG PET of the breasts and of the axillary regions was performed on 28 women with breast cancer. Transmission scans were acquired for attenuation correction after administration of FDG. Transverse and coronal slices and maximum intensity projections both with and without attenuation correction were documented in a standardized manner on film. Noncorrected images were displayed with an upper threshold of five times the mean activity in normal lung tissue. Attenuation corrected images were documented with an upper threshold of a standardized uptake value of five. Two independent nuclear medicine physicians, who were unaware of the results of clinical investigation, other imaging modalities and histopathologic findings, interpreted the images visually, noncorrected images first. Results: One hundred eighty-four of 189 lesions in 28 of 28 patients were found on attenuation-corrected and noncorrected images. Seventeen lesions were found in the breasts of 12 patients. In 18 patients, 31 axillary lesions were found. Moreover, 141 lesions representing distant metastases were detected in 18 patients. Attenuation-corrected images showed the same lesions in all patients but 2, in whom 5 of 189 small pulmonary lesions (2.6%) were not detected. Iterative reconstruction did not im prove detectability of these lesions on attenuation-corrected images. These lesions were confirmed by CT, which revealed diameters of < 1 cm. Conclusion: Attenuation correction by transmission measurement after injection may impair lesion detectability in PET for staging of breast cancer patients. When using the image modalities described, noncorrected PET images should be considered in image analysis.

Key Words: PET • breast cancer • attenuation correction • lesion detection




This article has been cited by other articles:


Home page
Ann. Surg. Oncol.Home page
P. J. Lovrics, V. Chen, G. Coates, S. D. Cornacchi, C. H. Goldsmith, C. Law, M. N. Levine, K. Sanders, and V. R. Tandan
A Prospective Evaluation of Positron Emission Tomography Scanning, Sentinel Lymph Node Biopsy, and Standard Axillary Dissection for Axillary Staging in Patients with Early Stage Breast Cancer
Ann. Surg. Oncol., September 1, 2004; 11(9): 846 - 853.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. Bai, P. E. Kinahan, D. Brasse, C. Comtat, D. W. Townsend, C. C. Meltzer, V. Villemagne, M. Charron, and M. Defrise
An Analytic Study of the Effects of Attenuation on Tumor Detection in Whole-Body PET Oncology Imaging
J. Nucl. Med., November 1, 2003; 44(11): 1855 - 1861.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J. Nuyts, S. Stroobants, P. Dupont, S. Vleugels, P. Flamen, and L. Mortelmans
Reducing Loss of Image Quality Because of the Attenuation Artifact in Uncorrected PET Whole-Body Images
J. Nucl. Med., August 1, 2002; 43(8): 1054 - 1062.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
D. Vranjesevic, J. E. Filmont, J. Meta, D. H. Silverman, M. E. Phelps, J. Rao, P. E. Valk, and J. Czernin
Whole-Body 18F-FDG PET and Conventional Imaging for Predicting Outcome in Previously Treated Breast Cancer Patients
J. Nucl. Med., March 1, 2002; 43(3): 325 - 329.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. O. Helal, P. Merlet, M.-E. Toubert, B. Franc, C. Schvartz, H. Gauthier-Koelesnikov, A. Prigent, and A. Syrota
Clinical Impact of 18F-FDG PET in Thyroid Carcinoma Patients with Elevated Thyroglobulin Levels and Negative 131I Scanning Results After Therapy
J. Nucl. Med., October 1, 2001; 42(10): 1464 - 1469.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
I. A. Zealley, S. J. Skehan, J. Rawlinson, G. Coates, C. Nahmias, and S. Somers
Selection of Patients for Resection of Hepatic Metastases: Improved Detection of Extrahepatic Disease with FDG PET
RadioGraphics, October 1, 2001; 21(90001): S55 - 69.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. Nakamoto, T. Saga, T. Ishimori, M. Mamede, K. Togashi, T. Higuchi, M. Mandai, S. Fujii, H. Sakahara, and J. Konishi
Clinical Value of Positron Emission Tomography with FDG for Recurrent Ovarian Cancer
Am. J. Roentgenol., June 1, 2001; 176(6): 1449 - 1454.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. S. Gambhir, J. Czernin, J. Schwimmer, D. H. S. Silverman, R. E. Coleman, and M. E. Phelps
A Tabulated Summary of the FDG PET Literature
J. Nucl. Med., May 1, 2001; 42(90050): 1S - 93.
[Full Text] [PDF]


Home page
RadiologyHome page
D. Delbeke, W. H. Martin, J. A. Patton, and M. P. Sandler
Value of Iterative Reconstruction,AttenuationCorrection,and Image Fusion in the Interpretation of FDG PET Images with an Integrated Dual-Head Coincidence Camera and X-Ray-based Attenuation Maps
Radiology, January 1, 2001; 218(1): 163 - 171.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1999 by the Society of Nuclear Medicine.