Department of Radiology and Faculty of Health Sciences, Okayama University Medical School, Okayama
Department of Radiology, Fukuyama National Hospital, Fukuyama, Japan
Correspondence: For correspondence or reprints contact: Yoshihiro Okumura, Department of Radiology, Okayama University Medical School, 2-5-1 Shikata-cho, Okayama 700-8558, Japan.
ABSTRACT
We assessed the ability of 201Tl planar scintigraphy and fine-needle aspiration (FNA) biopsy to differentiate malignant from benign lesions by comparing the findings of these techniques with those of surgical histopathology for 107 patients with 109 thyroid nodules. Methods: 201Tl(74 MBq) was injected intravenously, and an early image and a delayed image were acquired after 10 and 120 min, respectively, for 10 min each. For 201Tl planar scintigraphy, accumulation of the tracer in the nodules was visually scored and the nodules were grouped. Group A showed high activity in both early and delayed images. Group B revealed high activity in only the early image. Group C showed activity in the early image equal to that in normal tissues. Quantitative calculation of the washout rate was less than 0 in group Cl and 0 or higher in group CII. Group D revealed low activity in the early image and variable activity in the delayed image. Three differential diagnosis methods were used for 201Tl planar scintigraphy: method 1, in which only group A was considered malignant; method 2, in which both group A and group B were considered malignant; and method 3, in which groups A, B and Cl were considered malignant. FNA results were assessed and classified by experienced pathologists. Two differential diagnosis methods were used for FNA: method a, in which malignancy was assigned to class IV (probably malignant or higher), and method b, in which malignancy was assigned to class III (possibly malignant or higher). Results: Concerning 201Tl methods 1, 2 and 3, sensitivity was 74.0%, 84.0% and 92.0%, respectively; specificity was 83.1%, 64.4% and 54.2%, respectively; and accuracy was 78.9%, 73.4% and 71.6%, respectively. For FNA, method a and method b had a sensitivity of 36.0% and 50.0%, respectively, and a specificity of 96.6% and 84.7%, respectively. The accuracy of both methods was 68.8%. For follicular lesions, sensitivity ranged from 80.0% to 90.0% for 201Tl scintigraphy and from 10.0% to 30.0% for FNA. Conclusion: 201Tl planar scintigraphy was found to be easier to use and more accurate than FNA in the differentiation of diagnosis of benign and malignant thyroid nodules based on visual scoring combined with quantitative evaluation.
Key Words: 201Tl planar scintigraphy thyroid nodules fine-needle aspiration
This article has been cited by other articles:
![]() |
L. Hegedus, S. J. Bonnema, and F. N. Bennedbaek Management of Simple Nodular Goiter: Current Status and Future Perspectives Endocr. Rev., February 1, 2003; 24(1): 102 - 132. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |