|
|
||||||||
MRC Cyclotron Unit, Royal Postgraduate Medical School, Hammersmith Hospital, London, United Kingdom
Correspondence: For correspondence or reprints contact:Robert J.A. Harte, MD, c/o Pat M. Price, MD, MRC Cyclotron Unit, PET Oncology Group, Royal Postgraduate Medical School, Hammersmith Hospital, Du Cane Rd., London W12 ONN, United Kingdom.
ABSTRACT
Central to the assessment of variability of pharmacokinetic parameters is knowledge of bias and variability of the measurement technique, preventing observed differences from being ascribed inappropriate significance. This article presents an evaluation of sources of error in the measurement of normal tissue and tumor pharmacokinetics using 18F-labeled 5-fluorouracil (FU) and PET. Methods: A standard approach to data acquisition, processing and analysis was developed using a PET scanner, filtered backprojection reconstruction and region of interest analysis. Fourteen tracer 5-[18F]FU patient studies and a phantom study were completed, with 4 of the patient studies repeated 1 wk later. These data allowed evaluation of the overall reproducibility of the technique and the components of measurement variability due to tissue sampling. The effect of reconstruction technique and sampling region size on quantification was assessed using phantom data. Results: All measured radioactivity versus time curves were tissue specific. Week-to-week variability in the area under this curve (representing combined physiological and measurement difference) was 3% to +15% for liver and 9% to 16% for spleen and kidney. Metastasis variability was greatest at 20%. Visual and computer realign ment of the second paired study produced similar results. Interobserver effects were small compared to differences between studies. Conclusion: These resultsconfirm the feasibilityof using PET as a pharmacokinetic tool for 5-[18F]FU studies. Although overall experimental error (i.e., random variation in data acquisition, processing and analysis) was low, constraints in data interpretation emerged.
Key Words: PET 5-fluorine-18-fluorouracil pharmacokinetics measurement error
This article has been cited by other articles:
![]() |
D. S. Boss, R. V. Olmos, M. Sinaasappel, J. H. Beijnen, and J. H. M. Schellens Application of PET/CT in the Development of Novel Anticancer Drugs Oncologist, January 1, 2008; 13(1): 25 - 38. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. O. Aboagye, A. Saleem, V. J. Cunningham, S. Osman, and P. M. Price Extraction of 5-Fluorouracil by Tumor and Liver: A Noninvasive Positron Emission Tomography Study of Patients with Gastrointestinal Cancer Cancer Res., July 1, 2001; 61(13): 4937 - 4941. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |