JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 39 No. 8 1370-1376
© 1998 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Harte, R. J.A.
Right arrow Articles by Price, P. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Harte, R. J.A.
Right arrow Articles by Price, P. M.

Sources of Error in Tissue and Tumor Measurements of 5-[18F]Fluorouracil

Robert J.A. Harte, Julian C. Matthews, Susan M. O'Reilly and Pat M. Price

MRC Cyclotron Unit, Royal Postgraduate Medical School, Hammersmith Hospital, London, United Kingdom

Correspondence: For correspondence or reprints contact:Robert J.A. Harte, MD, c/o Pat M. Price, MD, MRC Cyclotron Unit, PET Oncology Group, Royal Postgraduate Medical School, Hammersmith Hospital, Du Cane Rd., London W12 ONN, United Kingdom.

ABSTRACT

Central to the assessment of variability of pharmacokinetic parameters is knowledge of bias and variability of the measurement technique, preventing observed differences from being ascribed inappropriate significance. This article presents an evaluation of sources of error in the measurement of normal tissue and tumor pharmacokinetics using 18F-labeled 5-fluorouracil (FU) and PET. Methods: A standard approach to data acquisition, processing and analysis was developed using a PET scanner, filtered backprojection reconstruction and region of interest analysis. Fourteen tracer 5-[18F]FU patient studies and a phantom study were completed, with 4 of the patient studies repeated 1 wk later. These data allowed evaluation of the overall reproducibility of the technique and the components of measurement variability due to tissue sampling. The effect of reconstruction technique and sampling region size on quantification was assessed using phantom data. Results: All measured radioactivity versus time curves were tissue specific. Week-to-week variability in the area under this curve (representing combined physiological and measurement difference) was –3% to +15% for liver and –9% to –16% for spleen and kidney. Metastasis variability was greatest at –20%. Visual and computer realign ment of the second paired study produced similar results. Interobserver effects were small compared to differences between studies. Conclusion: These resultsconfirm the feasibilityof using PET as a pharmacokinetic tool for 5-[18F]FU studies. Although overall experimental error (i.e., random variation in data acquisition, processing and analysis) was low, constraints in data interpretation emerged.

Key Words: PET • 5-fluorine-18-fluorouracil • pharmacokinetics • measurement error




This article has been cited by other articles:


Home page
The OncologistHome page
D. S. Boss, R. V. Olmos, M. Sinaasappel, J. H. Beijnen, and J. H. M. Schellens
Application of PET/CT in the Development of Novel Anticancer Drugs
Oncologist, January 1, 2008; 13(1): 25 - 38.
[Abstract] [Full Text] [PDF]


Home page
Cancer Res.Home page
E. O. Aboagye, A. Saleem, V. J. Cunningham, S. Osman, and P. M. Price
Extraction of 5-Fluorouracil by Tumor and Liver: A Noninvasive Positron Emission Tomography Study of Patients with Gastrointestinal Cancer
Cancer Res., July 1, 2001; 61(13): 4937 - 4941.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1998 by the Society of Nuclear Medicine.