JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 39 No. 4 591-598
© 1998 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hove, J. D.
Right arrow Articles by Phelps, M. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hove, J. D.
Right arrow Articles by Phelps, M. E.

Dual Spillover Problem in the Myocardial Septum with Nitrogen-13-Ammonia Flow Quantitation

Jens D. Hove, Sanjiv S. Gambhir, Klaus F. Kofoed, Henning Kelbæk, Heinrich R. Schelbert and Michael E. Phelps

Crump Institute for Biological Imaging, Division of Nuclear Medicine, Departments of Molecular and Medical Pharmacology and Biomathematics, University of California at Los Angeles School of Medicine, Los Angeles, California
Division of Cardiology, Medical Department B, The Heart Center, Rigshospitalet, Copenhagen, Denmark

Correspondence: For correspondence or reprints contact: Sanjiv Sam Gambhir, MD, PhD, Crump Institute for Biological Imaging, UCLA School of Medicine, A-222B CIBI, 700 Westwood Plaza, Los Angeles, CA 90095-1770.

ABSTRACT

Conventional cardiac PET modeling techniques for [13N]ammonia flow determination do not fully account for the effects of spillover of activity from the right ventricle (RV) onto the activity in the myocardial septum. The purpose of this study was to investigate and to quantitatively account and correct for this effect. Methods: Simulations were performed to determine the error introduced by conventional quantitation using septal time-activity curves, which only account for left ventricle (LV) spillover. Furthermore, we explored two separate methods to account for the dual spillover problem: direct estimation of the RV and LV spillover fractions incorporated into the [13N]ammonia model by using the LV and RV input functions in the fit and estimation of the relative dispersion and time shift between the LV and RV input functions by fitting using only the LV input function. The simulated curves were fitted using a two-compartment [13N]ammonia model. Flow estimates from the conventional model and the models including either of the two correction procedures were compared with canine microsphere data. Results: The influence of RV spillover on flow estimation in the septum is determined by several parameters (e.g., dispersion between the RV and LV input function). Depending on the value of these parameters,the septal flow may be underestimated by 0%–30%. The applied methods for correction of the dual spillover problem were comparable and allow for more accurate quantitation in the septum. The canine microsphere data revealed that flow underestimation in the septum is small but significant. Conclusion: Dual spillover in the myocardial septum can introduce significant errors in the estimation of flow by the conventional [13N]ammonia model fitting method, which does not properly account for the RV spillover. Adjusting for the RV spillover in one of the two proposed methods allows for more accurate quantitation of myocardial septal flow with [13N]ammonia PET data.

Key Words: PET • myocardial blood flow • septum • nitrogen-13-ammonia




This article has been cited by other articles:


Home page
JNMHome page
J. S. Lee, D. S. Lee, J. Y. Ahn, J. S. Yeo, G. J. Cheon, S.-K. Kim, K. S. Park, J.-K. Chung, and M. C. Lee
Generation of Parametric Image of Regional Myocardial Blood Flow Using H215O Dynamic PET and a Linear Least-Squares Method
J. Nucl. Med., October 1, 2005; 46(10): 1687 - 1695.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. A. Kaufmann and P. G. Camici
Myocardial Blood Flow Measurement by PET: Technical Aspects and Clinical Applications
J. Nucl. Med., January 1, 2005; 46(1): 75 - 88.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1998 by the Society of Nuclear Medicine.