JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 39 No. 2 361-365
© 1998 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Magnussen, J. S.
Right arrow Articles by Van der Wall, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Magnussen, J. S.
Right arrow Articles by Van der Wall, H.

Variability of Perceived Defect Size in Virtual Lung Scintigraphy

John S. Magnussen, Peter Chicco, Amanda W. Palmer, Douglas W. Mackey, Michael Magee, I. Provan C. Murray, George Bautovich, Kevin Allman, Geoffrey Storey and Hans Van der Wall

Department of Nuclear Medicine, Concord Hospital; Graduate School of Biomedicai Engineering, University of New South Wales; Department of Radiology, St. George Hospital; Nuclear Diagnostics; Department of Nuclear Medicine, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia

Correspondence: For correspondence or reprints contact: John S. Magnussen, MB, BS, Department of Nuclear Medicine, Concord Hospital, Hospital Rd., Concord, New South Wales 2139, Australia.

ABSTRACT

The diagnosis of pulmonary embolism is based on the presence of mismatched segmental or subsegmental defects. An important axiom is the classification of defect sizes into small, moderate and large. Little information about the recognition and classification of such defects has been published. We undertook a study of the perception of defect size using a model of the virtual scintigraphic anatomy of the lungs to address this issue. Methods: Segmental anatomy of the lungs was modeled with CT, cadaveric lungs and standard anatomical tests. The emission, scatter and attenuation of photons were modeled within these virtual lungs and the surrounding tissues. Single segmental lesions, each 100% of a segment, were created in eight projections and submitted for blinded reporting by four experienced nuclear medicine physicians to obtain their assessment of the size of each defect on two occasions. Results: Of the 144 defects submitted for reporting, 15% were reported as < 25% of a segment, 35% were reported as 25%–75% and 50% were reported as 75%–100%. The accuracy of each reporter and the intraobserver agreement were calculated; the weighted kappa value ranged from 0.34 to 0.60. The segmental defects that were most likely to be underestimated in size were in the right lower lobe. Conclusion: It is clear that segmental defect sizes were underestimated, particularly in the right lower lobe. Although the intraobserver agreement in reporting was fair, the accuracy of estimation was only 50%. The variability and inaccuracy might be reduced by the use of a guide to segmental anatomy.

Key Words: Monte Carlo simulation • lung scintigraphy • perception • defect size







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1998 by the Society of Nuclear Medicine.