ABSTRACT
In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Methods: Two groups of patients with 51Cr-EDTA clearance (CI) between 16 and 172 ml/min were studied. In Group I (n = 46), reference CI was determined as a multi plasma sample, single-injection method (CISM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference CI was determined by the Brøchner-Mortensen four-sample clearance method (CIBM). The plasma timeactivity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single sample clearance. Formula 1 was derived from the entire time activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Results: Chromium-51-EDTA CI calculated by Formula 1 was almost identical to the CI calculated by the reference CI method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA CI calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (p < 0.001), respectively. Conclusion: It is possible to get an accurate determi nation of 51Cr-EDTA CI from a single-plasma sample in adults by the mean sojourn time methodology. The determination is marginally more accurate (p < 0.001) if using a formula derived from the entire plasma time-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA CI tends slightly to overestimate GFR if used to calculate 51Cr-EDTA CI.
Key Words: single sample chromium-51-ethylenediaminetetraacetic acid clearance, glomerular filtration rate renal function
This article has been cited by other articles:
![]() |
N. J. Bird, C. Peters, A. R. Michell, and A. M. Peters Effect of extracellular fluid volume on single-sample measurement of glomerular filtration rate Nephrol. Dial. Transplant., August 19, 2008; (2008) gfn437v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Gref and K. Karp GFR determination in adults with a single-sample iohexol plasma clearance method based on the mean sojourn time Nephrol. Dial. Transplant., November 1, 2007; 22(11): 3166 - 3173. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Godfrey, M. J. Cuadrado, C. Fofi, I. Abbs, M. A. Khamashta, T. Nunan, and G. R. V. Hughes Chromium-51 ethylenediamine tetraacetic acid glomerular filtration rate: a better predictor than glomerular filtration rate calculated by the Cockcroft-Gault formula for renal involvement in systemic lupus erythematosus patients Rheumatology, March 1, 2001; 40(3): 324 - 328. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |