JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 39 No. 12 2022-2027
© 1998 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shimada, K.
Right arrow Articles by Masuda, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shimada, K.
Right arrow Articles by Masuda, Y.

High-Resolution Cardiac PET in Rabbits: Imaging and Quantitation of Myocardial Blood Flow

Kazuhiro Shimada, Katsuya Yoshida, Hiroyuki Tadokoro, Shinobu Kitsukawa, Akira Takami, Kazutoshi Suzuki, Shuji Tanada and Yoshiaki Masuda

Division of Advanced Technology for Medical Imaging, National Institute of Radiological Sciences, and Third Department of Internal Medicine, Chiba University School of Medicine, Chiba, Japan

Correspondence: For correspondence or reprints contact: Katsuya Yoshida, MD, Division of AdvancedTechnology for Medical Imaging, National Institute of Radiological Sciences, Anagawa4-9-1, Inage-ku, Chiba-shi, 263, Japan.

ABSTRACT

A high-resolution PET system for small animals was tested for its applicability to the investigation of regional myocardial blood flow (MBF) in rabbits. Methods: Nineteen measurements were performed in 10 closed-chest anesthetized rabbits at baseline and during infusions of adenosine (0.2 mg/kg/min) and propranolol (0.20–1.20 mg slow infusion) to obtain a wide range of MBF. Myocardial blood flow was assessed both by dynamic 13N-ammonia PET and by colored microspheres. Blood was withdrawn directly from the femoral artery, and arterial 13N activity was measured by coincidence type gamma detection system for the input function. Nitrogen-13 myocardial uptake was calculated by dividing the myocardial 13N activity by the integral value of the input function. Results: Three or four contiguous cross-sectional myocardial images were obtained after 13N-ammonia injection. The left ventricular wall and cardiac cavity were clearly visualized. Moreover, initial passage of the tracer through the heart was obtained with serial 10-sec PET images. Nitrogen-13 myocardial uptake correlated well with flow measured with microspheres (r = 0.88). Conclusion: Our cardiac PET system can be used for in vivo imaging and quantitation of MBF in small animals and may play an important role in the future study of animal models of cardiovascular diseases.

Key Words: PET • rabbits • myocardial blood flow




This article has been cited by other articles:


Home page
JNMHome page
I. Matsunari, F. Haas, N. T.B. Nguyen, G. Reidel, I. Wolf, R. Senekowitsch-Schmidtke, G. Stöcklin, and M. Schwaiger
Comparison of Sestamibi, Tetrofosmin, and Q12 Retention in Porcine Myocardium
J. Nucl. Med., May 1, 2001; 42(5): 818 - 823.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1998 by the Society of Nuclear Medicine.