JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 39 No. 10 1696-1702
© 1998 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hermansen, F.
Right arrow Articles by Lammertsma, A. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hermansen, F.
Right arrow Articles by Lammertsma, A. A.

Generation of Myocardial Factor Images Directly from the Dynamic Oxygen-15-Water Scan Without Use of an Oxygen-1 5-Carbon Monoxide Blood-Pool Scan

Flemming Hermansen, John Ashburner, Terry J. Spinks, Jaspal S. Kooner, Paolo G. Camici and Adriaan A. Lammertsma

PET Methodology and Cardiology Groups, Cyclotron Unit, MRC Clinical Sciences Centre, Hammersmith Hospital, London; Department of Cardiology, Royal Postgraduate Medical School, Hammersmith Hospital, London, United Kingdom

Correspondence: For correspondence or reprints contact: Flemming Hermansen, MD, PET Center, Aarhus General Hospital, 44 Norrebrogade, Aarhus C. Denmark DK-8000.

ABSTRACT

The measurement of regional myocardial blood flow (MBF) with H215O and PET requires an additional C15O blood-pool scan for the purpose of region of interest (ROI) definition. This additional scan results in a substantially increased radiation dose, study duration and risk of movement artifacts. Therefore, a method was developed to generate myocardial factor images directly from the dynamic H215O studyWithOuttheneedfora C15O scan. Methods: The factor sinograms were generated by means of linear dimension reduction of the dynamic sinograms,where the required variate and covariate factors (myocardial and blood time-activity curves) were modeled from the lung time-activity curve. The factor images were generated by iterative reconstruction. Results: No signfficant difference was found between MBF values from ROls drawn on the traditional images(usmng the C15O scan) and those drawn on the factor images. Conclusion: It is possible to generate myocardial images directly from the dynamo H215O study, so that the C15O scan can be omitted from MBF studies. The proposed method is robust and results in nearly optimal signal-to-noise ratios in the factor images.

Key Words: PET • myocardial blood flow • factor analysis • myocardial and biood-pool images

FOOTNOTES

Present address: Adriaan A. Lammertsma, PhD, PET Centre, Free University Hospital, Amsterdam, The Netherlands.




This article has been cited by other articles:


Home page
CJASNHome page
C. W. McIntyre, J. O. Burton, N. M. Selby, L. Leccisotti, S. Korsheed, C. S.R. Baker, and P. G. Camici
Hemodialysis-Induced Cardiac Dysfunction Is Associated with an Acute Reduction in Global and Segmental Myocardial Blood Flow
Clin. J. Am. Soc. Nephrol., January 1, 2008; 3(1): 19 - 26.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. P. Naoumova, H. Kindler, L. Leccisotti, M. Mongillo, M. T. Khan, C. Neuwirth, M. Seed, P. Holvoet, J. Betteridge, and P. G. Camici
Pioglitazone Improves Myocardial Blood Flow and Glucose Utilization in Nondiabetic Patients With Combined Hyperlipidemia: A Randomized, Double-Blind, Placebo-Controlled Study
J. Am. Coll. Cardiol., November 20, 2007; 50(21): 2051 - 2058.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. T. Siegrist, O. Gaemperli, P. Koepfli, T. Schepis, M. Namdar, I. Valenta, F. Aiello, S. Fleischmann, H. Alkadhi, and P. A. Kaufmann
Repeatability of Cold Pressor Test-Induced Flow Increase Assessed with H215O and PET
J. Nucl. Med., September 1, 2006; 47(9): 1420 - 1426.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
R Jagathesan, E Barnes, S D Rosen, R Foale, and P G Camici
Dobutamine-induced hyperaemia inversely correlates with coronary artery stenosis severity and highlights dissociation between myocardial blood flow and oxygen consumption
Heart, September 1, 2006; 92(9): 1230 - 1237.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. Chareonthaitawee, S. D. Christenson, J. L. Anderson, B. J. Kemp, D. O. Hodge, E. L. Ritman, and R. J. Gibbons
Reproducibility of Measurements of Regional Myocardial Blood Flow in a Model of Coronary Artery Disease: Comparison of H215O and 13NH3 PET Techniques
J. Nucl. Med., July 1, 2006; 47(7): 1193 - 1201.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
P M Elliott, H Kindler, J S Shah, B Sachdev, O E Rimoldi, R Thaman, M T Tome, W J McKenna, P Lee, and P G Camici
Coronary microvascular dysfunction in male patients with Anderson-Fabry disease and the effect of treatment with {alpha} galactosidase A
Heart, March 1, 2006; 92(3): 357 - 360.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
O. Rimoldi, K. P. Schafers, R. Boellaard, F. Turkheimer, L. Stegger, M. P. Law, A. A. Lammerstma, and P. G. Camici
Quantification of Subendocardial and Subepicardial Blood Flow Using 15O-Labeled Water and PET: Experimental Validation
J. Nucl. Med., January 1, 2006; 47(1): 163 - 172.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J. S. Lee, D. S. Lee, J. Y. Ahn, J. S. Yeo, G. J. Cheon, S.-K. Kim, K. S. Park, J.-K. Chung, and M. C. Lee
Generation of Parametric Image of Regional Myocardial Blood Flow Using H215O Dynamic PET and a Linear Least-Squares Method
J. Nucl. Med., October 1, 2005; 46(10): 1687 - 1695.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. A. Kaufmann, M. Namdar, F. Matthew, M. Roffi, S. V. Aschkenasy, B. van der Loo, G. Sutsch, T. F. Luscher, and R. Jenni
Novel Doppler Assessment of Intracoronary Volumetric Flow Reserve: Validation Against PET in Patients With or Without Flow-Dependent Vasodilation
J. Nucl. Med., August 1, 2005; 46(8): 1272 - 1277.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Watabe, H. Jino, N. Kawachi, N. Teramoto, T. Hayashi, Y. Ohta, and H. Iida
Parametric Imaging of Myocardial Blood Flow with 15O-Water and PET Using the Basis Function Method
J. Nucl. Med., July 1, 2005; 46(7): 1219 - 1224.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. Jagathesan, P. A. Kaufmann, S. D. Rosen, O. E. Rimoldi, F. Turkeimer, R. Foale, and P. G. Camici
Assessment of the Long-Term Reproducibility of Baseline and Dobutamine-Induced Myocardial Blood Flow in Patients with Stable Coronary Artery Disease
J. Nucl. Med., February 1, 2005; 46(2): 212 - 219.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. A. Kaufmann and P. G. Camici
Myocardial Blood Flow Measurement by PET: Technical Aspects and Clinical Applications
J. Nucl. Med., January 1, 2005; 46(1): 75 - 88.
[Full Text] [PDF]


Home page
CirculationHome page
P. A. Kaufmann, O. Rimoldi, T. Gnecchi-Ruscone, R. S. Bonser, T. F. Luscher, and P. G. Camici
Systemic Inhibition of Nitric Oxide Synthase Unmasks Neural Constraint of Maximal Myocardial Blood Flow in Humans
Circulation, September 14, 2004; 110(11): 1431 - 1436.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. A. Wyss, P. Koepfli, K. Mikolajczyk, C. Burger, G. K. von Schulthess, and P. A. Kaufmann
Bicycle Exercise Stress in PET for Assessment of Coronary Flow Reserve: Repeatability and Comparison with Adenosine Stress
J. Nucl. Med., February 1, 2003; 44(2): 146 - 154.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
P. Iozzo, P. Chareonthaitawee, D. Dutka, D. J. Betteridge, E. Ferrannini, and P. G. Camici
Independent Association of Type 2 Diabetes and Coronary Artery Disease With Myocardial Insulin Resistance
Diabetes, October 1, 2002; 51(10): 3020 - 3024.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. P. Schafers, T. J. Spinks, P. G. Camici, P. M. Bloomfield, C. G. Rhodes, M. P. Law, C. S.R. Baker, and O. Rimoldi
Absolute Quantification of Myocardial Blood Flow with H215O and 3-Dimensional PET: An Experimental Validation
J. Nucl. Med., August 1, 2002; 43(8): 1031 - 1040.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. A. Lammertsma
Myocardial Perfusion in 3 Dimensions
J. Nucl. Med., August 1, 2002; 43(8): 1041 - 1043.
[Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
C. J. Hoekstra, S. G. Stroobants, O. S. Hoekstra, E. F. Smit, J. F. Vansteenkiste, and A. A. Lammertsma
Measurement of Perfusion in Stage IIIA-N2 Non-Small Cell Lung Cancer Using H215O and Positron Emission Tomography
Clin. Cancer Res., July 1, 2002; 8(7): 2109 - 2115.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. Rajappan, O. E. Rimoldi, D. P. Dutka, B. Ariff, D. J. Pennell, D. J. Sheridan, and P. G. Camici
Mechanisms of Coronary Microcirculatory Dysfunction in Patients With Aortic Stenosis and Angiographically Normal Coronary Arteries
Circulation, January 29, 2002; 105(4): 470 - 476.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
F. Frouin, P. Merlet, Y. Bouchareb, V. Frouin, J.-L. Dubois-Rande, A. De Cesare, A. Herment, A. Syrota, and A. Todd-Pokropek
Validation of Myocardial Perfusion Reserve Measurements Using Regularized Factor Images of H215O Dynamic PET Scans
J. Nucl. Med., December 1, 2001; 42(12): 1737 - 1746.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J. S. Lee, D. S. Lee, J. Y. Ahn, G. J. Cheon, S.-K. Kim, J. S. Yeo, K. Seo, K. S. Park, J.-K. Chung, and M. C. Lee
Blind Separation of Cardiac Components and Extraction of Input Function from H215O Dynamic Myocardial PET Using Independent Component Analysis
J. Nucl. Med., June 1, 2001; 42(6): 938 - 943.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J. Y. Ahn, D. S. Lee, J. S. Lee, S.-K. Kim, G. J. Cheon, J. S. Yeo, S.-A. Shin, J.-K. Chung, and M. C. Lee
Quantification of Regional Myocardial Blood Flow Using Dynamic H215O PET and Factor Analysis
J. Nucl. Med., May 1, 2001; 42(5): 782 - 787.
[Abstract] [Full Text]


Home page
JNMHome page
H. Iida, Y. Tamura, K. Kitamura, P. M. Bloomfield, S. Eberl, and Y. Ono
Histochemical Correlates of 15O-Water-Perfusable Tissue Fraction in Experimental Canine Studies of Old Myocardial Infarction
J. Nucl. Med., October 1, 2000; 41(10): 1737 - 1745.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. A. Kaufmann, T. Gnecchi-Ruscone, M. di Terlizzi, K. P. Schafers, T. F. Luscher, and P. G. Camici
Coronary Heart Disease in Smokers : Vitamin C Restores Coronary Microcirculatory Function
Circulation, September 12, 2000; 102(11): 1233 - 1238.
[Abstract] [Full Text] [PDF]


Home page
NeurologyHome page
T. Gnecchi-Ruscone, X. Bernard, P. Pierre, D. Anderson, N. Legg, H. Enahoro, P. D. O. Winter, A. Crisp, J. A. Melin, and P. G. Camici
Effect of naratriptan on myocardial blood flow and coronary vasodilator reserve in migraineurs
Neurology, July 12, 2000; 55(1): 95 - 99.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. A. Kaufmann, T. Gnecchi-Ruscone, K. P. Schafers, T. F. Luscher, and P. G. Camici
Low density lipoprotein cholesterol and coronary microvascular dysfunction in hypercholesterolemia
J. Am. Coll. Cardiol., July 1, 2000; 36(1): 103 - 109.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
P. Iozzo, P. Chareonthaitawee, M. Di Terlizzi, D. J. Betteridge, E. Ferrannini, and P. G. Camici
Regional myocardial blood flow and glucose utilization during fasting and physiological hyperinsulinemia in humans
Am J Physiol Endocrinol Metab, May 1, 2002; 282(5): E1163 - E1171.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1998 by the Society of Nuclear Medicine.