JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 38 No. 7 1161-1168
© 1997 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Graham, M. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Graham, M. M.

Physiologic Smoothing of Blood Time-Activity Curves for PET Data Analysis

Michael M. Graham

Department of Radiology, Division of Nuclear Medicine, University of Washington, Seattle, Washington

Correspondence: For correspondence or reprints contact: Michael M. Graham, PhD, MD, Division of Nuclear Medicine, Box 356113, University of Washington, Seattle, WA 98195-6113.

ABSTRACT

Blood or plasma time-activity curves (TACs) are used as the input function for mathematical models of tracer kinetics in several applications including PET. Uncertainty associated with both the blood data and the PET tissue data can result in uncertainty in the estimates of metabolic rates, blood flow, etc. Methods: This article presents an approach to reduce the uncertainty in the blood TAC by fitting a model to the curve. The model includes a choice of bolus or infusion input and has three compartments (plasma, interstitial fluid and tissue fluid) with exchange between them. There is a parameter for loss from the plasma compartment. To test the utility of smoothing blood TACs with this approach, a program was set up, using the fluorodeoxyglucose (FDG) model, with simulated noisy blood and tissue TACs. The smoothed blood TAC was compared to a linearly interpolated TAC as the input function with a compartimentai model parameter estimation program and with graphical analysis. Results: With a well sampled blood TAC (19 points), the model approach is somewhat more accurate than linear interpolation if the s.d. of noise added to the data exceeded 10%. With sparsely sampled blood TACs (five points) or with a large gap in the blood TAC, the modeled approach was markedly better. For graphical analysis, the model smoothed TAC was also more accurate, although, in general, the results were not as sensitive to the input function. Conclusion: This approach, using a physiologically reasonable model to smooth the blood TAC, is a useful aid in PET data analysis, particularly when the data are quite noisy or when there are large gaps in the data.

Key Words: kinetic analysis • blood sampling • PET




This article has been cited by other articles:


Home page
JNMHome page
M. M. Graham, M. Muzi, A. M. Spence, F. O'Sullivan, T. K. Lewellen, J. M. Link, and K. A. Krohn
The FDG Lumped Constant in Normal Human Brain
J. Nucl. Med., September 1, 2002; 43(9): 1157 - 1166.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
S. R. Golish, J. D. Hove, H. R. Schelbert, and S. S. Gambhir
A Fast Nonlinear Method for Parametric Imaging of Myocardial Perfusion by Dynamic 13N-Ammonia PET
J. Nucl. Med., June 1, 2001; 42(6): 924 - 931.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1997 by the Society of Nuclear Medicine.