JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 38 No. 2 219-223
© 1997 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Butler, S. P.
Right arrow Articles by Quinn, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Butler, S. P.
Right arrow Articles by Quinn, R. J.

Detection of Postoperative Deep-Venous Thrombosis Using Technetium-99m-Labeled Tissue Plasminogen Activator

S. Patrick Butler, Tan Rahman, Samantha J. Boyd, Sharon L. Parkes and Richard J. Quinn

Department of Nuclear Medicine, St. George Hospital, Sydney, Australia

Correspondence: For correspondence or reprints contact: S. P. Butler, MD, Dept. of Nuclear Medicine, St. George Hospital, Sydney 2217, Australia.

ABSTRACT

The current noninvasive methods of deep-venous thrombosis (DVT) detection in the asymptomatic patient are sufficiently inaccurate so as to preclude their routine use. This present study reports the accuracy of scintigraphic scanning with 99mTc-rt-PA in asymptomatic postoperative patients using contrast venography as the gold standard. Methods: Fifty-three consecutive postarthroplasty patients (30 THR, 23 11 TKR)(16 women, 37 men; mean age 71 yr, range 52-85 yr) underwent scintigraphic scanning with 99mTc-rt-PA and contrast venography, on the operated leg, in order to assess the accuracy of this new technique in these asymptomatic patients. Results: Eighty-four segments were of diagnostic quality on contrast venography. Of the 15 thrombosed segments, 14 had positive scans. In the 69 nonthrombosed segments, 63 had negative scans. Thus, scintigraphic scanning with 99mTc-rt-PAhad a sensitivity of 93% and a specificity of 91%. Conclusion: This study demonstrated that scintigraphic scanning with modified 99mTc-rt-PA is accurate in the detection of DVT in patients undergoing total hip or total knee arthroplasty.

Key Words: technetium-99m • recombinant tissue plasminogen activator • deep-venous thrombosis




This article has been cited by other articles:


Home page
JNMHome page
T. Brighton, J. Janssen, and S. P. Butler
Aging of Acute Deep Vein Thrombosis Measured by Radiolabeled 99mTc-rt-PA
J. Nucl. Med., June 1, 2007; 48(6): 873 - 878.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
W. H. Geerts, J. A. Heit, G. P. Clagett, G. F. Pineo, C. W. Colwell, F. A. Anderson Jr., and H. B. Wheeler
Prevention of Venous Thromboembolism
Chest, January 1, 2001; 119(1_suppl): 132S - 175S.
[Full Text] [PDF]


Home page
Vasc MedHome page
J.-L. Cracowski, J.-L. Bosson, F. Baloul, C. Moirant, M. Hunt, P. Merloz, P. Carpentier, and A. Franco
Early development of deep-vein thrombosis following hip fracture surgery: the role of venous wall thickening detected by B-mode ultrasonography
Vascular Medicine, November 1, 1998; 3(4): 269 - 274.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1997 by the Society of Nuclear Medicine.