JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 38 No. 11 1784-1786
© 1997 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kabasakal, L.
Right arrow Articles by Önsel, c.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kabasakal, L.
Right arrow Articles by Önsel, c.

Simplified Technetium-99m-EC Clearance in Adults from a Single Plasma Sample

Levent Kabasakal, A. Fuat Yapar, Kutlan Özker, Ebru Alkan, Saadet Atay, Nihat Özçelik and çetin Önsel

Department of Nuclear Medicine, Cerrahpasa, Medical Faculty, Istanbul, Turkey

Correspondence: For correspondence or reprints contact: Levent Kabasakal, MD, Cerraphasa Tip Fakültesi, Nükleer Tip Anabilim Dali Aksaray Istanbul, 34303 Turkey.

ABSTRACT

Technetium-99m-EC has recently been introduced as an alternative renal tubular agent to 131I. iodohippurate (OIH). It has been shown that 99mTc-EC clearance shows strong correlation with OIH clearance and it is possible to estimate effective renal plasma flow. In routine clinical studies, it is practical to use one or two plasma sample methods instead of multiple plasma samples for clearance determination. An attempt was made to determine 99mTc-EC clearance with one sample method. Methods: Data from 72 subjects were collected. To increase the range of renal function, two anuric hemodialysis patients were also included. Clearances were determined by the open two-compartment model. Results: The clearance range was 12 ml/min to 660 ml/min with a mean of275 ± 117 ml/min. Analysis of correlation was made by Tauxe's method. The least standard error of estimation (s.e.e. = 32.71 ml/min) and the best correlation (r = 0.97) between the theoretical volume distribution and the clearance estimations were obtained from the 54-min plasma sample. Conclusion: This study suggests that EC clearance could be determined by a simplified single-sample method with an acceptable s.e.e.

Key Words: technetium-99m-ethylenedicisteine • clearance determination • radionuclide renography • effective renal plasma flow • renal function




This article has been cited by other articles:


Home page
J. Am. Soc. Nephrol.Home page
B. L. KASISKE, M. A. VAZQUEZ, W. E. HARMON, R. S. BROWN, G. M. DANOVITCH, R. S. GASTON, D. ROTH, J. D. SCANDLING JR., and G. G. SINGER
Recommendations for the Outpatient Surveillance of Renal Transplant Recipients
J. Am. Soc. Nephrol., October 1, 2000; 11(2007): S1 - S86.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1997 by the Society of Nuclear Medicine.