JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 37 No. 4 588-593
© 1996 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Russell, C. D.
Right arrow Articles by Dubovsky, E. V.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Russell, C. D.
Right arrow Articles by Dubovsky, E. V.

Measurement of Renal Function with Technetium-99m-MAG3 in Children and Adults

Charles D. Russell , Andrew T. Taylor and Eva V. Dubovsky

Division of Nuclear Medicine, University of Alabama Hospital and Nuclear Medicine Service, Department of Veterans Affairs Medical Center—Birmingham, Birmingham, Alabama
Department of Nuclear Medicine, Emory University Hospital, Atlanta, Georgia

Correspondence: For correspondence or reprints contact: Charles D. Russell, MD, PhD, Division of Nuclear Medicine, University of Alabama Hospital 619-19th St. South, Birmingham, AL.

ABSTRACT

A single-injection, single-sample procedure for measuring 99mTc-MAG3 clearance is presented that incorporates scaling for patient size and is valid for both children and adults. Methods: The procedure is based on an empirical formula in which all measurements are expressed in dimensionless combinations. The formula was obtained by fitting data collected from 122 adults and 80 children at several centers. Results: All results were scaled to standard adult surface area and are presented in units of ml/min/1.73 m2. For adult subjects, the residual standard deviation (r.s.d.) calculated from a single sample at 45 min was found to be 23, using the plasma clearance calculated from a multi-sample clearance curve as a reference. This did not differ significantly from the value of 22 obtained with our previous formula, which was valid for adults only. For pediatric subjects, an r.s.d. of 24 was calculated by the new formula from a single sample at 35 min; a comparable value of 33 was found using a pediatric formula previously published. Conclusion: The new clearance formula is recommended as a replacement for the formula we previously published, since it is based on a larger and more diverse subject population, and since it now holds for children as well, with no loss of accuracy for adult subjects.

Key Words: kidney • technetium-99m-MAG3 • radionuclide clearance




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. P. Esteves, A. Taylor, A. Manatunga, R. D. Folks, M. Krishnan, and E. V. Garcia
99mTc-MAG3 Renography: Normal Values for MAG3 Clearance and Curve Parameters, Excretory Parameters, and Residual Urine Volume.
Am. J. Roentgenol., December 1, 2006; 187(6): W610 - W617.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
E. V. Garcia and A. Taylor
Reply: an expert system for the detection of renal obstruction.
J. Nucl. Med., August 1, 2006; 47(8): 1394a - 11395.
[Full Text] [PDF]


Home page
JNMHome page
C. D. Russell
A Bayesian 3-Compartment Model for 99mTc-MAG3 Clearance
J. Nucl. Med., August 1, 2003; 44(8): 1357 - 1361.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. D. Russell, A. T. Taylor Jr, and E. V. Dubovsky
A Bayesian Regression Model for Plasma Clearance
J. Nucl. Med., June 1, 2002; 43(6): 762 - 766.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1996 by the Society of Nuclear Medicine.