Division of Nuclear Medicine, University of Alabama Hospital and Nuclear Medicine Service, Department of Veterans Affairs Medical Center—Birmingham, Birmingham, Alabama
Department of Nuclear Medicine, Emory University Hospital, Atlanta, Georgia
Correspondence: For correspondence or reprints contact: Charles D. Russell, MD, PhD, Division of Nuclear Medicine, University of Alabama Hospital 619-19th St. South, Birmingham, AL.
ABSTRACT
A single-injection, single-sample procedure for measuring 99mTc-MAG3 clearance is presented that incorporates scaling for patient size and is valid for both children and adults. Methods: The procedure is based on an empirical formula in which all measurements are expressed in dimensionless combinations. The formula was obtained by fitting data collected from 122 adults and 80 children at several centers. Results: All results were scaled to standard adult surface area and are presented in units of ml/min/1.73 m2. For adult subjects, the residual standard deviation (r.s.d.) calculated from a single sample at 45 min was found to be 23, using the plasma clearance calculated from a multi-sample clearance curve as a reference. This did not differ significantly from the value of 22 obtained with our previous formula, which was valid for adults only. For pediatric subjects, an r.s.d. of 24 was calculated by the new formula from a single sample at 35 min; a comparable value of 33 was found using a pediatric formula previously published. Conclusion: The new clearance formula is recommended as a replacement for the formula we previously published, since it is based on a larger and more diverse subject population, and since it now holds for children as well, with no loss of accuracy for adult subjects.
Key Words: kidney technetium-99m-MAG3 radionuclide clearance
This article has been cited by other articles:
![]() |
F. P. Esteves, A. Taylor, A. Manatunga, R. D. Folks, M. Krishnan, and E. V. Garcia 99mTc-MAG3 Renography: Normal Values for MAG3 Clearance and Curve Parameters, Excretory Parameters, and Residual Urine Volume. Am. J. Roentgenol., December 1, 2006; 187(6): W610 - W617. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. V. Garcia and A. Taylor Reply: an expert system for the detection of renal obstruction. J. Nucl. Med., August 1, 2006; 47(8): 1394a - 11395. [Full Text] [PDF] |
||||
![]() |
C. D. Russell A Bayesian 3-Compartment Model for 99mTc-MAG3 Clearance J. Nucl. Med., August 1, 2003; 44(8): 1357 - 1361. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Russell, A. T. Taylor Jr, and E. V. Dubovsky A Bayesian Regression Model for Plasma Clearance J. Nucl. Med., June 1, 2002; 43(6): 762 - 766. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |