JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 37 No. 1 22-25
© 1996 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cordes, M.
Right arrow Articles by Felix, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cordes, M.
Right arrow Articles by Felix, R.

Iodine-123-Iodo-Lisuride SPECT in Parkinson's Disease

Michael Cordes, Johannes Hierholzer, Ludwig Schelosky, Annette Schrag, Wolf S. Richter, Hermann Eichstädt, Paul E. Schulze, Werner Poewe and Roland Felix

Neurology Clinic, Institute for Diagnostic Medicine, Rudolf Virchow University Clinic, Free University, Berlin, Germany

Correspondence: For correspondence or reprints contact: Michael Cordes, MD, Section of Nuclear Medicine, Institute of Radiology and Nuclear Medicine, St. Theresienkrankenhaus, Martin-Richter-Str. 43, 90489 Nuremberg, Germany.

ABSTRACT

Recently, [123I]iodo-lisuride was synthesized for possible applications in SPECT studies. The purpose of this investigation was to compare the striatal binding and kinetics of this radioligand in patients with Parkinson's disease and normal controls. Methods: Six patients with Parkinson's disease and three normal controls were examined. After intravenous injection of 111 MBq [123I]iodo-lisuride, sequential SPECT examinations at 20, 40, 80 and 120 min were performed. For each SPECT series the basal ganglia-to-cerebellum ratio of tracer accumulation was calculated. In one patient a repeat SPECT examination was undertaken under identical conditions to test the reproducibility of the procedure. In two other patients a second SPECT examination was performed after injection of cold lisuride as a receptor saturation study. In addition, the time course of the radioactivity was measured in the plasma and red blood cells in each individual. Results: In both patients and controls, the highest tracer accumulation was found within the striatum. The basal ganglia-to-cerebellum ratio was 1.182 and 1.303 at 20 min, 1.353 and 1.450 at 40 min, 1.490 and 1.533 at 80 min, 1.550 and 1.583 at 120 min for patients and controls, respectively, which was not statistically different. In the saturation study, 50 µg and 100 µg cold lisuride led to a 28% and 33% reduction, respectively, of the basal ganglia-to-cerebellum ratio at 120 min. The ligand showed a rapid decline in plasma and red blood cells. The percent injected dose per liter was calculated to be 1.6 and 0.9, respectively, for plasma and red blood cells at 20 min. Conclusion: Iodine-123-iodo-lisuride SPECT seems useful for imaging intact striatal dopamine D2 receptors in patients with Parkinson's disease and may provide clinically relevant information for quantitative assessment of the availability and integrity of dopamine D2 receptors.

Key Words: iodine-123-iodo-lisuride • Parkinson's disease • dopamine D2 receptors • SPECT




This article has been cited by other articles:


Home page
JNMHome page
E. E. Camargo
Brain SPECT in Neurology and Psychiatry
J. Nucl. Med., April 1, 2001; 42(4): 611 - 623.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1996 by the Society of Nuclear Medicine.