JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 7 1125-1128
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lee, J. D.
Right arrow Articles by Park, C. Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lee, J. D.
Right arrow Articles by Park, C. Y.

Increased Thallium-201 Uptake in Collapsed Lung: A Pitfall in Scintigraphic Evaluation of Central Bronchogenic Carcinoma

Jong Doo Lee, Byung Hee Lee, Se Kyu Kim, Kyung Young Chung, Dong Hwan Shin and Chang Yun Park

Department of Diagnostic Radiology, Pulmonology, Chest Surgery and Pathology, Yonsei University College of Medicine, Seoul, Korea

Correspondence: For correspondence or reprint requests contact: Jong Doo Lee, MD, Dept. of Diagnostic Radiology, Yonsei University, College of Medicine, 134 Shinchon-dong, Seodaemun-gu, Seoul, 120-752, Korea.

ABSTRACT

This study evaluated whether 201Tl scintigraphy can differentiate a central bronchogenic cancer from a distal collapse consolidation. Methods: Nine patients with squamous carcinoma with collapse confirmed by surgery and pathology were included. All patients underwent SPECT 1 hr after an intravenous injection of 3 mCi of 201Tl. Four-hour delayed SPECT was performed in five of the nine patients. The thallium activity in tumor and collapse was visually assessed on the basis of the pathologic findings. The specimens were prepared to have the same orientation and level with the SPECT image. Results: The tumor activity appeared higher than that of the collapse in four patients, equal in three patients and lower in two patients. Both collapsed lung with and without superimposed inflammation also showed increased thallium activity. Delayed SPECT aided in tumor detection within a collapsed lung in only two of the five patients. Conclusion: Our study illustrates the need for caution in the interpretation of thallium scintigraphy in patients with central bronchogenic cancer and distal collapse.

Key Words: lung cancer • thallium-201 • SPECT




This article has been cited by other articles:


Home page
JNMHome page
K. Higashi, Y. Ueda, T. Sakuma, H. Seki, M. Oguchi, M. Taniguchi, S. Taki, H. Tonami, S. Katsuda, and I. Yamamoto
Comparison of [18F]FDG PET and 201Tl SPECT in Evaluation of Pulmonary Nodules
J. Nucl. Med., October 1, 2001; 42(10): 1489 - 1496.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.