JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 6 999-1005
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, T. R.
Right arrow Articles by Sabharwal, C. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, T. R.
Right arrow Articles by Sabharwal, C. L.

Measurement of Global and Regional Left Ventricular Function by Cardiac PET

Tom R. Miller, Jerold W. Wallis, Brian R. Landy, Robert J. Gropler and Chander L. Sabharwal

The Edward Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri

Correspondence: For correspondence or reprints contact: Tom R. Miller, MD, PhD, The Edward Mallinckrodt Institute of Radiology, 510 S. Kingshighway Blvd., St. Louis, MO 63110.

ABSTRACT

To permit assessment by positron tomography of left ventricular mechanical function, methods were developed to measure ejection fraction and regional wall motion and produce realistic images of the beating heart from ECG-gated PET data Methods: Following red cell labeling with 15O-carbon monoxide, seven-slice PET data were collected in list mode and reformatted into 16 time frames. Volume-rendered cine images were created by the depth-weighted maximum-activity method. To determine the left ventricular ejection fraction, background was subtracted in voxels outside the heart and the cubic datasets were rotated to the angle with the best septal separation. Depth weighting was applied to simulate a 99mTc study, and the beating images were rendered by summing counts along parallel projection rays. These techniques were validated in 16 patients by comparison with planar studies performed with 99mTc-red cells. Results: Visual grading of regional wall motion yielded exact agreement between the PET and 99mTc methods in 62% of walls with agreement within one grade in 94%. Assessment of quantitative regional wall motion agreed closely with an independent threshold edge detection method. Conclusion: PET techniques have been developed to measure left-ventricular ejection fraction and regional wall motion and to produce realistic beating images of the cardiac blood pool. This information can be obtained at the same time as measurements of perfusion and metabolism and in the same spatial orientation, thereby permitting quantitative assessment by positron tomography of global and regional mechanical function in relation to flow and metabolism.

Key Words: PET • left ventricular function • computers




This article has been cited by other articles:


Home page
JNMHome page
K. Rajappan, L. Livieratos, P. G. Camici, and D. J. Pennell
Measurement of Ventricular Volumes and Function: A Comparison of Gated PET and Cardiovascular Magnetic Resonance
J. Nucl. Med., June 1, 2002; 43(6): 806 - 810.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.