JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 5 824-831
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maes, B.D.
Right arrow Articles by Vantrappen, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maes, B.D.
Right arrow Articles by Vantrappen, G.

Combined Carbon-13-Glycine/Carbon-14-Octanoic Acid Breath Test to Monitor Gastric Emptying Rates of Liquids and Solids

B.D. Maes, Y.F. Ghoos, B.J. Geypens, G. Mys, M.I. Hiele, P.J. Rutgeerts and G. Vantrappen

Department of Medicine, Division of Gastroenterolgy and Gastrointestinal Research Centre, University Hospital Gasthuisberg
Department of Mathematics, Leuven, Belgium

Correspondence: For correspondence or reprints contact: Prof. Dr. P. Rutgeerts, Department of Medicine and Medical Research, University Hospital Gasthuisberg, B-3000 Leuven, Belgium.

ABSTRACT

The aim of the present study was to develop a dual-carbon-labeled breath test for simultaneously measuring gastric emptying rates of liquids and solids with significantly less radiation burden to the patient than the radioscintigraphic technique. Methods: A test meal was used in which the liquid phase was labeled with two markers, i.e., 3.7 MBq of 111In-DTPA and 100 mg of 13C-glycine; the solid phase also was dually labeled with 110 MBq of 99mTc-albumin colloid and 74 kBq of 14C-octanoic acid. Simultaneous radioscintigraphic and breath-test measurements were performed in 27 subjects, 10 normal controls and 17 patients with dyspeptic symptoms. Mathematic analysis of the excretion rate of labeled CO2 allowed the definition of four parameters, i.e., the gastric emptying coefficient, the gastric half-emptying time, the peak excretion time and the lag phase. Results: There was a good to excellent correlation between the gastric emptying coefficient and the scintigraphic half-emptying time (r = 0.74 for liquids and r = 0.88 for solids), between the half-emptying time determined by breath test and the scintigraphic half-emptying time (r = 0.91 for liquids and r = 0.92 for solids), between the peak excretion time and the scintigraphic half-emptying time (r = 0.91 for liquids and r = 0.96 for solids) and between the lag phase of solid emptying determined by both techniques (r = 0.89). Conclusion: The dual carbon-labeled breath test is a valid, minimally invasive technique to measure the gastric emptying rate of both liquids and solids.

Key Words: gastric emptying • breath test • radioscintigraphy • carbon-14-octanoic acid • carbon-13-glycine • indium-111-DTPA • technetium-99m-albumin




This article has been cited by other articles:


Home page
GutHome page
G Karamanolis, P Caenepeel, J Arts, and J Tack
Determinants of symptom pattern in idiopathic severely delayed gastric emptying: gastric emptying rate or proximal stomach dysfunction?
Gut, January 1, 2007; 56(1): 29 - 36.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
T Kitazawa, B De Smet, K Verbeke, I Depoortere, and T L Peeters
Gastric motor effects of peptide and non-peptide ghrelin agonists in mice in vivo and in vitro
Gut, August 1, 2005; 54(8): 1078 - 1084.
[Abstract] [Full Text] [PDF]


Home page
GutHome page
J Arts, P Caenepeel, K Verbeke, and J Tack
Influence of erythromycin on gastric emptying and meal related symptoms in functional dyspepsia with delayed gastric emptying
Gut, April 1, 2005; 54(4): 455 - 460.
[Abstract] [Full Text] [PDF]


Home page
Drug Metab. Dispos.Home page
D. R. J. Kuypers, K. Claes, P. Evenepoel, B. Maes, and Y. Vanrenterghem
THE RATE OF GASTRIC EMPTYING DETERMINES THE TIMING BUT NOT THE EXTENT OF ORAL TACROLIMUS ABSORPTION: SIMULTANEOUS MEASUREMENT OF DRUG EXPOSURE AND GASTRIC EMPTYING BY CARBON-14-OCTANOIC ACID BREATH TEST IN STABLE RENAL ALLOGRAFT RECIPIENTS
Drug Metab. Dispos., December 1, 2004; 32(12): 1421 - 1425.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Gastrointest. Liver Physiol.Home page
G. Sarnelli, D. Sifrim, J. Janssens, and J. Tack
Influence of sildenafil on gastric sensorimotor function in humans
Am J Physiol Gastrointest Liver Physiol, November 1, 2004; 287(5): G988 - G992.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
C. E.M. De Block, I. H. De Leeuw, P. A. Pelckmans, D. Callens, E. Maday, and L. F. Van Gaal
Delayed Gastric Emptying and Gastric Autoimmunity in Type 1 Diabetes
Diabetes Care, May 1, 2002; 25(5): 912 - 917.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
P. D. Klein
13C Breath Tests: Visions and Realities
J. Nutr., May 1, 2001; 131(5): 1637S - 1642.
[Abstract] [Full Text]


Home page
Am. J. Clin. Nutr.Home page
F. Mariotti, S. Mahe, C. Luengo, R. Benamouzig, and D. Tome
Postprandial modulation of dietary and whole-body nitrogen utilization by carbohydrates in humans
Am. J. Clinical Nutrition, October 1, 2000; 72(4): 954 - 962.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Gastrointest. Liver Physiol.Home page
B. D. Maes, G. Mys, B. J. Geypens, P. Evenepoel, Y. F. Ghoos, and P. J. Rutgeerts
Gastric emptying flow curves separated from carbon-labeled octanoic acid breath test results
Am J Physiol Gastrointest Liver Physiol, July 1, 1998; 275(1): G169 - G175.
[Abstract] [Full Text] [PDF]


Home page
J. Nutr.Home page
T. H. Vesa, P. R. Marteau, F. B. Briet, M.-C. Boutron-Ruault, and J.-C. Rambaud
Raising Milk Energy Content Retards Gastric Emptying of Lactose in Lactose-Intolerant Humans with Little Effect on Lactose Digestion
J. Nutr., December 1, 1997; 127(12): 2316 - 2320.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
P. Schadewaldt, B. Schommartz, G. Wienrich, H. Brosicke, R. Piolot, and D. Ziegler
Application of isotope-selective nondispersive infrared spectrometry (IRIS) for evaluation of [13C]octanoic acid gastric-emptying breath tests: comparison with isotope ratio–mass spectrometry (IRMS)
Clin. Chem., March 1, 1997; 43(3): 518 - 522.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.