JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 4 652-663
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ficaro, E. P.
Right arrow Articles by Schwaiger, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ficaro, E. P.
Right arrow Articles by Schwaiger, M.

Comparison of Americium-241 and Technetium-99m as Transmission Sources for Attenuation Correction of Thallium-201 SPECT Imaging of the Heart

Edward P. Ficaro, Jeffrey A. Fessler, W. Leslie Rogers and Markus Schwaiger

Department of Internal Medicine, Division of Nuclear Medicine, The University of Michigan Medical Center, Ann Arbor, Michigan

Correspondence: For correspondence or reprints contact: Edward Ficaro, PhD, The University of Michigan Hospitals, 1500 E. Medical Center Dr., Ann Arbor, MI 48109.

ABSTRACT

This study compares the ability of 241Am and 99mTc to estimate 201Tl attenuation maps while minimizing the loss in the precision of the emission data. Methods: A triple-head SPECT system with either an 241Am or 99mTc line source opposite a fan-beam collimator was used to estimate attenuation maps of the thorax of an anthropomorphic phantom. Linear attenuation values at 75 keV for 201Tl were obtained by linear extrapolation of the measured values from 241Am and 99mTc. Results: Lung and soft-tissue estimates from both isotopes showed excellent agreement to within 3% of the measured values for 201Tl. Linear extrapolation did not yield satisfactory estimates for bone from either 241Am (+11.7%) or 99mTc (-15.3%). Patient data were used to estimate the dependence of crosstalk on patient size. Contamination from 201Tl in the transmission window was 5–6 times greater for 241Am compared to 99mTc, while the contamination in the 201Tl data in the transmission-emission detector head (head 1) was 4–5 times greater for 99mTc compared to 241Am. No contamination was detected in the 201Tl emission data of heads 2 and 3 from 241Am, whereas the 99mTc produced a small crosstalk component giving a signal-to-crosstalk ratio near 20:1. Measurements with a fillable chest phantom estimated the mean error introduced into the data from the removal of the crosstalk. Conclusion: Based on the measured data, 241AM is a suitable transmission source for simultaneous transmission-emission tomography for 201Tl cardiac studies.

Key Words: transmission tomography • SPECT • attenuation correction • cardiac imaging




This article has been cited by other articles:


Home page
JNMHome page
H. Zaidi and B. Hasegawa
Determination of the Attenuation Map in Emission Tomography
J. Nucl. Med., February 1, 2003; 44(2): 291 - 315.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
K. Van Laere, M. Koole, T. Kauppinen, M. Monsieurs, L. Bouwens, and R. Dierck
Nonuniform Transmission in Brain SPECT Using 201Tl, 153Gd, and 99mTc Static Line Sources: Anthropomorphic Dosimetry Studies and Influence on Brain Quantification
J. Nucl. Med., December 1, 2000; 41(12): 2051 - 2062.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. P. Ficaro, J. A. Fessler, P. D. Shreve, J. N. Kritzman, P. A. Rose, and J. R. Corbett
Simultaneous Transmission/Emission Myocardial Perfusion Tomography : Diagnostic Accuracy of Attenuation-Corrected 99mTc-SestamibiSingle-Photon Emission Computed Tomography
Circulation, February 1, 1996; 93(3): 463 - 473.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.