Department of Radiology, Emory University Hospital, Atlanta, Georgia
University of New Mexico, College of Pharmacy/Radiopharmacy, Albuquerque, New Mexico
Correspondence: For correspondence and reprints contact: Dennis Eshima, PhD, Emory University Hospital, Dept. of Radiology, PET Center, 1364 Clifton Rd. NE, Atlanta, GA 30322.
ABSTRACT
Technetium-99-MAG3 is a renal tubular function agent. However, sporadic liver and gallbladder visualization have raised questions about kit stability, impurities and nonrenal routes of excretion. To address these issues, studies were conducted to optimize the labeling efficiency of the TechneScan MAG3 kit and to evaluate the hepatobiliary excretion of the MAG3 complex. Methods: Thirty-six vials of the commercial formulation of 99mTc-MAG3 were prepared according to manufacturer's instructions and evaluated for radiochemical purity using two methods: a combination of high-performance liquid chromatograpy and paper chromatography (HPLC/PC); and the manufacturers miniature chromatography system (Sep-Pak procedure). Results: The labeling efficiency was significantly higher when the kit was reconstituted with 10 ml (96.6%) of saline versus 5 ml (91.4%)(p < 0.01). The radiochemical purity of the kits remained stable for up to 6 hr, but the purity determined by Sep-Pak averaged 2.5% higher than that determined by HPLC procedures (p < 0.01). Rat studies to evaluate renal and hepatobiliary elimination of MAG3 showed no difference in the %ID excreted into the urine by 60 min in all groups of animals studied. However, the %ID excreted into the bile was significantly higher for the kit formulation than the HPLC-purified MAG3, 9.9% versus 6.6% (p = 0.0475). Conclusion: The radiochemical purity of the TechneScan MAG3 kit can be improved by reconstituting with larger volumes. In addition, the studies in rats suggest that fasting or kit impurities may be a contributing factor to increased hepatobiliary visualization in patient studies.
Key Words: technetium-99m-MAG3 hepatobiliary excretion radiochemical purity
This article has been cited by other articles:
![]() |
S. Seetharaman, J. R. Ballinger, and M. H. Sosabowski Simplified Method for Determining the Radiochemical Purity of 99mTc-MAG3. J. Nucl. Med. Technol., September 1, 2006; 34(3): 179 - 183. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. T. Taylor, M. Lipowska, L. Hansen, E. Malveaux, and L. G. Marzilli 99mTc-MAEC Complexes: New Renal Radiopharmaceuticals Combining Characteristics of 99mTc-MAG3 and 99mTc-EC J. Nucl. Med., May 1, 2004; 45(5): 885 - 891. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Shikano, Y. Kanai, K. Kawai, N. Ishikawa, and H. Endou Transport of 99mTc-MAG3 via Rat Renal Organic Anion Transporter 1 J. Nucl. Med., January 1, 2004; 45(1): 80 - 85. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Russell A Bayesian 3-Compartment Model for 99mTc-MAG3 Clearance J. Nucl. Med., August 1, 2003; 44(8): 1357 - 1361. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Arroyo, H. B. Semaan, K. D. Minkus, and Y. P. Patel Factors Affecting the Hepatobiliary Excretion of 99mTc-MAG3: Its Clinical Significance in Routine Renography J. Nucl. Med. Technol., March 1, 2003; 31(1): 18 - 20. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |