JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 2 349-355
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shattuck, L. A.
Right arrow Articles by Payne, S. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shattuck, L. A.
Right arrow Articles by Payne, S. E.

Evaluation of the Hepatobiliary Excretion of Technetium-99m-MAG3 and Reconstitution Factors Affecting Radiochemical Purity

Lorie A. Shattuck, Dennis Eshima, Andrew T. Taylor, Jr., Tamara L. Anderson, David L. Graham, Frank A. Latino and Suzanne E. Payne

Department of Radiology, Emory University Hospital, Atlanta, Georgia
University of New Mexico, College of Pharmacy/Radiopharmacy, Albuquerque, New Mexico

Correspondence: For correspondence and reprints contact: Dennis Eshima, PhD, Emory University Hospital, Dept. of Radiology, PET Center, 1364 Clifton Rd. NE, Atlanta, GA 30322.

ABSTRACT

Technetium-99-MAG3 is a renal tubular function agent. However, sporadic liver and gallbladder visualization have raised questions about kit stability, impurities and nonrenal routes of excretion. To address these issues, studies were conducted to optimize the labeling efficiency of the TechneScan MAG3 kit and to evaluate the hepatobiliary excretion of the MAG3 complex. Methods: Thirty-six vials of the commercial formulation of 99mTc-MAG3 were prepared according to manufacturer's instructions and evaluated for radiochemical purity using two methods: a combination of high-performance liquid chromatograpy and paper chromatography (HPLC/PC); and the manufacturers miniature chromatography system (Sep-Pak procedure). Results: The labeling efficiency was significantly higher when the kit was reconstituted with 10 ml (96.6%) of saline versus 5 ml (91.4%)(p < 0.01). The radiochemical purity of the kits remained stable for up to 6 hr, but the purity determined by Sep-Pak averaged 2.5% higher than that determined by HPLC procedures (p < 0.01). Rat studies to evaluate renal and hepatobiliary elimination of MAG3 showed no difference in the %ID excreted into the urine by 60 min in all groups of animals studied. However, the %ID excreted into the bile was significantly higher for the kit formulation than the HPLC-purified MAG3, 9.9% versus 6.6% (p = 0.0475). Conclusion: The radiochemical purity of the TechneScan MAG3 kit can be improved by reconstituting with larger volumes. In addition, the studies in rats suggest that fasting or kit impurities may be a contributing factor to increased hepatobiliary visualization in patient studies.

Key Words: technetium-99m-MAG3 • hepatobiliary excretion • radiochemical purity




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
S. Seetharaman, J. R. Ballinger, and M. H. Sosabowski
Simplified Method for Determining the Radiochemical Purity of 99mTc-MAG3.
J. Nucl. Med. Technol., September 1, 2006; 34(3): 179 - 183.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. T. Taylor, M. Lipowska, L. Hansen, E. Malveaux, and L. G. Marzilli
99mTc-MAEC Complexes: New Renal Radiopharmaceuticals Combining Characteristics of 99mTc-MAG3 and 99mTc-EC
J. Nucl. Med., May 1, 2004; 45(5): 885 - 891.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
N. Shikano, Y. Kanai, K. Kawai, N. Ishikawa, and H. Endou
Transport of 99mTc-MAG3 via Rat Renal Organic Anion Transporter 1
J. Nucl. Med., January 1, 2004; 45(1): 80 - 85.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
C. D. Russell
A Bayesian 3-Compartment Model for 99mTc-MAG3 Clearance
J. Nucl. Med., August 1, 2003; 44(8): 1357 - 1361.
[Abstract] [Full Text] [PDF]


Home page
J. Nucl. Med. Technol.Home page
A. J. Arroyo, H. B. Semaan, K. D. Minkus, and Y. P. Patel
Factors Affecting the Hepatobiliary Excretion of 99mTc-MAG3: Its Clinical Significance in Routine Renography
J. Nucl. Med. Technol., March 1, 2003; 31(1): 18 - 20.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.