JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 10 1586-1592
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Williams, B. R.
Right arrow Articles by Anderson, B. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Williams, B. R.
Right arrow Articles by Anderson, B. A.

A Retrospective Study of the Diagnostic Accuracy of a Community Hospital-Based PET Center for the Detection of Coronary Artery Disease Using Rubidium-82

Byron R. Williams, Nizar A. Mullani, Donald E. Jansen and Bradley A. Anderson

Saint Joseph's Hospital PET Center, Atlanta, Georgia
University of Texas Medical School, Houston, Texas
Kennestone PET Center, Marietta, Georgia

Correspondence: For correspondence or reprints contact: Nizar A. Mullani, Division of Cardiology, Suite 4.258, University of Texas Medical School, 6431 Fannin St., Houston, TX 77025.

ABSTRACT

A retrospective analysis has been earned out to determine the diagnostic accuracy of PET of the heart with 82Rb at a community hospital based center. Methods: Utilization statistics were derived from a total of 1460 patients scanned for the first 36 mo of the center's operation. Diagnostic accuracy for detection of coronary artery disease (CAD) was assessed using three readers blinded to the clinical information. A total of 287 rest and dipyridamole-stress scans of patients who had coronary angiograms within 6 mo of the PET scan were selected by the computer for this study. Each rest/stress scan was read by at least two of the three readers. Results: The average sensitivity for all three readers was 87% for greater than 67% diameter stenosis and the average specificity was 88% for myocardial regions perfused by normal coronary arteries. The average accuracy was 88% for patients with greater than 67% diameter stenosis. Sensitivity and accuracy improved to 92% and 91% respectively for stenosis greater than 90% in diameter. Conclusion: These results compare well with published results from major hospital-based centers and the recently published results from a private PET center in Georgia.

Key Words: PET • rubidium-82 • coronary artery disease • sensitivity • specificity • accuracy • PET utilization




This article has been cited by other articles:


Home page
JNMHome page
C. A. Santana, R. D. Folks, E. V. Garcia, L. Verdes, R. Sanyal, J. Hainer, M. F. Di Carli, and F. P. Esteves
Quantitative 82Rb PET/CT: Development and Validation of Myocardial Perfusion Database
J. Nucl. Med., July 1, 2007; 48(7): 1122 - 1128.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. Yoshinaga, B. J.W. Chow, K. Williams, L. Chen, R. A. deKemp, L. Garrard, A. Lok-Tin Szeto, M. Aung, R. A. Davies, T. D. Ruddy, et al.
What is the Prognostic Value of Myocardial Perfusion Imaging Using Rubidium-82 Positron Emission Tomography?
J. Am. Coll. Cardiol., September 5, 2006; 48(5): 1029 - 1039.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J.-W. Lin, R. R. Sciacca, R.-L. Chou, A. F. Laine, and S. R. Bergmann
Quantification of Myocardial Perfusion in Human Subjects Using 82Rb and Wavelet-Based Noise Reduction
J. Nucl. Med., February 1, 2001; 42(2): 201 - 208.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.