JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 35 No. 1 113-119
© 1994 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Faraggi, M.
Right arrow Articles by Bok, B. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Faraggi, M.
Right arrow Articles by Bok, B. D.

The Influence of Tracer Localization on the Electron Dose Rate Delivered to the Cell Nucleus

Marc Faraggi, Isabelle Gardin, Claire de Labriolle-Vaylet, Jean-Luc Moretti and Bernard D. Bok

Nuclear Medicine Department, Bichat Hospital, Paris
Nuclear Medicine Department, Beaujon Hospital, Clichy
Nuclear Medicine Department, Saint Antoine Hospital, Paris
Nuclear Medicine Department, Avicenne Hospital, Bobigny, France

Correspondence: For correspondence and reprints contact: M. Faraggi, MD, PhD, Nuclear Medicine Department, Hôpital Bichat, 46, rue Henri Huchard, F 75018 Paris, France.

ABSTRACT

The radiation dose rate delivered by electron emissions of 99mTc, 123I, 111In, 67Ga and 201Tl was evaluated at the subcellular level. Methods: Spherical models of sources were used to simulate various cellular localizations of radionuclides. These models were applied to large lymphocytes, assuming uniform distributions of radioactivity throughout the nucleus, the cytoplasm or the cell membrane surface. Results: The graphs of the absorbed dose rate plotted according to the distance from the center of the cell show that the dose rate strongly depends on the subcellular distribution of the radioisotope. The absorbed dose rate D(0) at the center of the cell delivered by a constant cellular radioactivity of 99mTc, 123I, 111In, 67Ga and 201Tl is respectively 94, 21, 18, 74 and 76 times higher if the radioactivity is localized within the cell nucleus than if it is situated only on the cell membrane. D(0) for subcellular localizations was compared to D(0) obtained by assuming uniform distribution of radioactivity throughout the cell. This latter assumption may underestimate the dose rate from 2.8- to 3.2-fold if the tracer is exclusively localized within the nucleus or overestimate from 4.3- to 30-fold if the tracer is localized within the cytoplasm or on the cell membrane, depending on the radionuclide. Conclusion: Such findings show that the localization of radiopharmaceuticals at the subcellular level plays a crucial role in determining the actual dose delivered to the cell nucleus in diagnostic nuclear medicine procedures.

Key Words: dose rate • electron • microdosimetry • diagnostic • intracellular distribution • radiopharmaceuticals




This article has been cited by other articles:


Home page
JNMHome page
C. A. Boswell and M. W. Brechbiel
Auger Electrons: Lethal, Low Energy, and Coming Soon to a Tumor Cell Nucleus Near You
J. Nucl. Med., December 1, 2005; 46(12): 1946 - 1947.
[Full Text] [PDF]


Home page
JNMHome page
C. Nguyen, M. Faraggi, A.-L. Giraudet, C. de Labriolle-Vaylet, T. Aparicio, F. Rouzet, M. Mignon, S. Askienazy, and I. Sobhani
Long-Term Efficacy of Radionuclide Therapy in Patients with Disseminated Neuroendocrine Tumors Uncontrolled by Conventional Therapy
J. Nucl. Med., October 1, 2004; 45(10): 1660 - 1668.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
R. M. Reilly, D. A. Scollard, J. Wang, H. Mondal, P. Chen, L. A. Henderson, B. M. Bowen, and K. A. Vallis
A Kit Formulated Under Good Manufacturing Practices for Labeling Human Epidermal Growth Factor with 111In for Radiotherapeutic Applications
J. Nucl. Med., April 1, 2004; 45(4): 701 - 708.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1994 by the Society of Nuclear Medicine.