JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 34 No. 9 1587-1594
© 1993 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Turkington, T. G.
Right arrow Articles by Coleman, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Turkington, T. G.
Right arrow Articles by Coleman, R. E.

Accuracy of Registration of PET, SPECT and MR Images of a Brain Phantom

Timothy G. Turkington, Ronald J. Jaszczak, Charles A. Pelizzari, C. Craig Harris, James R. MacFall, John M. Hoffman and R. Edward Coleman

Department of Radiology, Duke University Medical Center, Durham, North Carolina
Department of Radiation Oncology, University of Chicago, Chicago, Illinois

Correspondence: For correspondence and reprints contact: Timothy Turkington, Ph.D., Nuclear Medicine/Radiology, Duke University Medical Center, Box 3949, Durham, NC 27710.

ABSTRACT

Accuracy of a surface-fitting algorithm for three-dimensional image registration of single photon emission computed tomography (SPECT), positron emission tomography (PET), and magnetic resonance (MR) images was tested using a three dimensional, water-fillable brain phantom. Multislice or volume image sets were acquired for each modality. Small fiducial mark are were attached to assess accuracy of surface fitting and provide an alternate fitting technique. A maximum gradient technique was found to work well for SPECT and PET edge detection. Transformation parameters for translation, rotation and scaling were determined by surface fit to match each SPECT and PET scan with MR images. Using the markers, overall translation errors were found to be <2 mm in each direction and rotational errors <2 degrees in every case. Errors for specific internal regions were also determined to be <2 mm for most regions, with only a few fits resulting in errors >3 mm for some cortical regions. Results indicate surface fitting to be sufficiently accurate for visual comparison of registered images and for enhanced SPECT and PET region of interest (ROI) determination and image reconstruction.




This article has been cited by other articles:


Home page
RadiologyHome page
Y. Nakamoto, B. B. Chin, D. L. Kraitchman, L. P. Lawler, L. T. Marshall, and R. L. Wahl
Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies
Radiology, June 1, 2003; 227(3): 817 - 824.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
Y. Nakamoto, M. Osman, C. Cohade, L. T. Marshall, J. M. Links, S. Kohlmyer, and R. L. Wahl
PET/CT: Comparison of Quantitative Tracer Uptake Between Germanium and CT Transmission Attenuation-Corrected Images
J. Nucl. Med., September 1, 2002; 43(9): 1137 - 1143.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. P. Ko and M. Betke
Chest CT: Automated Nodule Detection and Assessment of Change over Time--Preliminary Experience
Radiology, January 1, 2001; 218(1): 267 - 273.
[Abstract] [Full Text]


Home page
Arch. Dis. Child.Home page
R O Robinson, C D Ferrie, M Capra, and M N Maisey
Positron emission tomography and the central nervous system
Arch. Dis. Child., September 1, 1999; 81(3): 263 - 270.
[Full Text]


Home page
Am. J. Neuroradiol.Home page
R. E. Hogan, V. J. Lowe, and R. D. Bucholz
Triple-Technique (MR Imaging, Single-Photon Emission CT, and CT) Coregistration for Image-Guided Surgical Evaluation of Patients with Intractable Epilepsy
AJNR Am. J. Neuroradiol., June 1, 1999; 20(6): 1054 - 1058.
[Abstract] [Full Text]


Home page
J. Neurol. Neurosurg. PsychiatryHome page
R E. Hogan, M. J Cook, D. W Binns, P. M Desmond, C. J Kilpatrick, V. L Murrie, and K. F Morris
Perfusion patterns in postictal 99mTc-HMPAO SPECT after coregistration with MRI in patients with mesial temporal lobe epilepsy
J. Neurol. Neurosurg. Psychiatry, August 1, 1997; 63(2): 235 - 239.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1993 by the Society of Nuclear Medicine.