JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


The Journal of Nuclear Medicine Vol. 34 No. 8 1341-1348
© 1993 by Society of Nuclear Medicine
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cooper, J. A.
Right arrow Articles by McCandless, B. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cooper, J. A.
Right arrow Articles by McCandless, B. K.

Detection of Patient Motion During Tomographic Myocardial Perfusion Imaging

Jeffrey A. Cooper, Paul H. Neumann and Brian K. McCandless

Department of Radiology, Albany Medical College, Albany, New York

Correspondence: For correspondence and reprints contact: Jeffrey A. Cooper, MD, Nuclear Medicine, A-72, 47 Scotland Ave., Albany Medical Center, Albany, NY 12208.

ABSTRACT

We compared the effectiveness of four methods for detecting patient motion during tomographic myocardial perfusion imaging: visual inspection of a cine of the raw data, cross-correlation, diverging squares and a new method called two-dimensional fit. The methods were evaluated for their ability to detect the presence of motion, localize the camera angle at which motion occurred and measure the distance of motion. Patient motion was simulated by shifting motion-free images and then masking their periphery so that the field of view did not move on the image matrix. None of the methods detected 3.25 mm of motion with clinically useful accuracies. Visual inspection, cross-correlation and two-dimensional fit most accurately detected axial patient motion (p < 0.05), whereas cross-correlation most accurately detected lateral motion (p < 0.05). For axial motion, cross-correlation and two-dimensional fit most accurately localized the camera angle at which patient motion occurred (p < 0.05). For lateral motion, cross-correlation most accurately localized patient motion (p < 0.05). Two-dimensional fit measured the distance of axial patient motion to ± 1.1 mm and measured the distance of lateral motion to ±8.7 mm. All other methods frequently overestimated or underestimated the distance of motion by > 13 mm. We conclude that cross-correlation adequately screens tomographic myocardial perfusion studies for both axial and lateral patient motion, although visual inspection is adequate for detection of axial motion. Cross-correlation best localizes the camera angle at which the motion occurred. Two-dimensional fit is the only method studied that accurately measures the distance of motion.




This article has been cited by other articles:


Home page
J. Nucl. Med. Technol.Home page
J. M. Wheat and G. M. Currie
Impact of Patient Motion on Myocardial Perfusion SPECT Diagnostic Integrity: Part 2
J. Nucl. Med. Technol., September 1, 2004; 32(3): 158 - 163.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
N. Matsumoto, D. S. Berman, P. B. Kavanagh, J. Gerlach, S. W. Hayes, H. C. Lewin, J. D. Friedman, and G. Germano
Quantitative Assessment of Motion Artifacts and Validation of a New Motion-Correction Program for Myocardial Perfusion SPECT
J. Nucl. Med., May 1, 2001; 42(5): 687 - 694.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE
Copyright © 1993 by the Society of Nuclear Medicine.